netconfcentral logo

bbf-selt

HTML

bbf-selt@2019-06-11



  module bbf-selt {

    yang-version 1.1;

    namespace "urn:bbf:yang:bbf-selt";

    prefix bbf-selt;

    include bbf-selt-base;
    include bbf-selt-pointers;
    include bbf-selt-pmd;
    include bbf-selt-pmd-control-body;
    include bbf-selt-pmd-status-body;
    include bbf-selt-pmd-profiles;
    include bbf-selt-pmd-profile-body;
    include bbf-selt-processing-profiles;
    include bbf-selt-processing-profile-body;
    include bbf-selt-result-parameters;
    include bbf-selt-pmd-measurement-parameter-body;
    include bbf-selt-processing-derived-parameter-body;

    organization
      "Broadband Forum <https://www.broadband-forum.org>
Common YANG Work Area";

    contact
      "Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN";

    description
      "This module contains a collection of YANG definitions for
supporting Single Ended Line Test (SELT) as defined in ITU
G.996.2.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.";

    revision "2019-06-11" {
      description
        "Amendment 2.
* Approval Date:    2019-06-11
* Publication Date: 2019-06-11.";
      reference
        "TR-355a2: YANG Modules for FTTdp Management
        	  <https://www.broadband-forum.org/technical/download/
        		 TR-355_Amendment-2.pdf>";

    }

    revision "2018-10-01" {
      description
        "Amendment 1.
* Approval Date:    2018-10-01
* Publication Date: 2018-10-01.";
      reference
        "TR-355a1: YANG Modules for FTTdp Management
        	  <https://www.broadband-forum.org/technical/download/
        		 TR-355_Amendment-1.pdf>";

    }

    revision "2017-11-27" {
      description
        "Corrigendum 2 (fixes to the previous revision).
* Approval Date:    see revision date above.
* Publication Date: 2018-01-19.";
      reference
        "TR-355c2: YANG Modules for FTTdp Management
        	  <https://www.broadband-forum.org/technical/download/
        		 TR-355_Corrigendum-2.pdf>";

    }

    revision "2017-03-13" {
      description
        "Corrigendum 1 (fixes to the initial revision).
* Approval Date:    see revision date above.
* Publication Date: 2017-04-12.";
      reference
        "TR-355c1: YANG Modules for FTTdp Management
        	  <https://www.broadband-forum.org/technical/download/
        		 TR-355_Corrigendum-1.pdf>";

    }

    revision "2016-07-18" {
      description
        "Initial revision.
* Approval Date:    see revision date above.
* Publication Date: 2016-08-05.";
      reference
        "TR-355: YANG Modules for FTTdp Management
        	<https://www.broadband-forum.org/technical/download/
        		 TR-355.pdf>";

    }


    // features

    feature selt-p {
      description
        "Indicates support for Single Ended Line Test Processing
(SELT-P) profiles.";
      reference
        "ITU-T G.996.2 annex B";

    }

    feature extended-bandwidth-selt-uer {
      description
        "Indicates support for extended bandwidth Single Ended Line Test
(SELT) for reporting Uncalibrated Echo Response (UER).";
    }

    feature extended-bandwidth-selt-qln {
      description
        "Indicates support for extended bandwidth Single Ended Line Test
(SELT) for reporting Quiet Line Noise (QLN).";
    }

    feature extended-bandwidth-selt-tflog {
      description
        "Indicates support for extended bandwidth Single Ended Line Test
(SELT) for reporting the logarithmic power transfer function
Tflog(f).";
    }

    // typedefs
    typedef pmd-function {
      type enumeration {
        enum "uer-measurement" {
          value 1;
          description
            "Triggers the Central Office (CO) Single Ended Line Test
Physical Medium Dependent (SELT-PMD) to start a
Uncalibrated Echo Response (UER) measurement.";
          reference
            "ITU-T G.996.2 clause A.2.3.1 (SELT-UME-C)";

        }
        enum "qln-measurement" {
          value 2;
          description
            "Triggers the Central Office (CO) Single Ended Line Test
Physical Medium Dependent (SELT-PMD) to start a Quiet Line
Noise (QLN) measurement.";
          reference
            "ITU-T G.996.2 clause A.2.3.3 (SELT-QME-C)";

        }
      }
      description
        "The Central Office (CO) Single Ended Line Test Physical Medium
Dependent (SELT-PMD) function.";
    }

    typedef uer-measurement-duration {
      type uint8 {
        range "5..240";
      }
      units "1 second";
      description
        "This parameter is the maximum allowed time for Singe Ended
Line Test (SELT) Uncalibrated Echo Response (UER) measurement,
between the time of the start command written by the
Single Ended Line Test Physical Medium Dependent Management
Entity (SELT-PMD-ME), and the time the result is available for
read operation by SELT-PMD-ME.

NOTE - The above duration includes internal pre-processing and
       post-processing.

It is configurable between 5 seconds and 240 seconds, in steps
of 1 second.";
      reference
        "ITU-T G.996.2 clause A.2.1.1 (SELT-UER-MMD-C,
        SELT-UER-MMD-R)";

    }

    typedef qln-measurement-duration {
      type uint8 {
        range "1..240";
      }
      units "1 second";
      description
        "This parameter is the maximum allowed time for Singe Ended
Line Test (SELT) Quiet Line Noise (QLN) measurement, between
the time of the start command written by the Single Ended Line
Test Physical Medium Dependent Management Entity (SELT-PMD-ME),
and the time the result is available for read operation by
SELT-PMD-ME.

NOTE - The above duration includes internal pre-processing and
       post-processing.

It is configurable between 1 second and 240 seconds, in steps
of 1 second.";
      reference
        "ITU-T G.996.2 clause A.2.1.2 (SELT-QLN-MMD-C,
        SELT-QLN-MMD-R)";

    }

    typedef pmd-profile-ref {
      type leafref {
        path "/bbf-selt:selt/bbf-selt:profiles/bbf-selt:pmd-profile/bbf-selt:name";
      }
      description
        "Used to reference a Physical Medium Dependent (PMD) profile.";
    }

    typedef pmd-result {
      type enumeration {
        enum
          "no-measurement-results-available" {
          value 0;
          description
            "No measurement results are available when no mesurement has
been performed yet or after measurement results have been
deleted.";
        }
        enum
          "measurement-failed-results-invalid" {
          value 1;
          description
            "The measurement results are invalid after the most recent
measurement failed.";
        }
        enum
          "measurement-succeeded-results-valid" {
          value 2;
          description
            "The measurement results are valid after the most recent
measurement succeeded.";
        }
      }
      description
        "The overall results of the SELT PMD measurement.";
    }

    typedef sub-carrier-index {
      type uint16 {
        range "0..8191";
      }
      description
        "Identifies a sub-carrier.";
    }

    typedef per-sub-carrier-uint8 {
      type binary {
        length "0..8192";
      }
      description
        "A binary type where each octet represents data belonging to
a sub-carrier group. The first octet represents sub-carrier
group 0 and the last octet represents the sub-carrier
group (length - 1).";
    }

    typedef per-sub-carrier-int32-tuple {
      type binary {
        length "0..65536";
      }
      description
        "A binary type where each group of 8 octets represents a tuple.
A tuple consists of two 4-octet groups and represents data
belonging to a sub-carrier. The first tuple represents
sub-carrier group 0 and the last tuple represents sub-carrier
group (length/8 - 1). In each 4-octet group in the
tuple, the most significant byte is loaded first. The order of
the tuples is determined by the node to which this type is
associated.";
    }

    typedef per-sub-carrier-uint16 {
      type binary {
        length "0..16384";
      }
      description
        "A binary type where each pair of octets represents data
belonging to a sub-carrier group. The first pair represents
sub-carrier group 0 and the last represents sub-carrier
group (length/2 - 1).";
    }

    // groupings
    grouping selt-pmd-control {
      description
        "Defines the parameters contained in the PMD control object.";
      leaf uer-measurement-enable-c {
        type boolean;
        default "false";
        status deprecated;
        description
          "If true, triggers the Central Office (CO) Single Ended Line
Test Physical Medium Dependent (SELT-PMD) to start a
Uncalibrated Echo Response(UER) measurement.

A configuration change back to 'false' is required before
initiating another update.";
        reference
          "ITU-T G.996.2 clause A.2.3.1 (SELT-UME-C)";

      }

      leaf qln-measurement-enable-c {
        type boolean;
        default "false";
        status deprecated;
        description
          "If true, triggers the Central Office (CO) Single Ended Line
Test Physical Medium Dependent (SELT-PMD) to start a Quiet
Line Noise(QLN) measurement.

A configuration change back to 'false' is required before
initiating another update.";
        reference
          "ITU-T G.996.2 clause A.2.3.3 (SELT-QME-C)";

      }
    }  // grouping selt-pmd-control

    grouping pmd-control {
      description
        "Physical Medium Dependent (PMD) control configuration.";
      leaf pmd-control {
        type enumeration {
          enum "disable" {
            value 0;
            description
              "The Central Office (CO) Single Ended Line Test Physical
Medium Dependent (SELT-PMD) is not configured for a
measurement.";
          }
          enum "enable" {
            value 1;
            description
              "The Central Office (CO) Single Ended Line Test Physical
Medium Dependent (SELT-PMD) is configured for a
measurement.";
          }
        }
        default "disable";
        description
          "The Central Office (CO) Single Ended Line Test Physical
Medium Dependent (SELT-PMD) is by default 'disable'. When
'disable', the line is in normal operation (e.g., in the L0
state if the line is configured with AdminStatus=up). When
'enable', the Access Node (AN)/Distribution Point Unit (DPU)
Maintenance Entity (ME) shall force the line to the L3
state.";
      }

      action request-pmd-function-c {
        description
          "A measurement is by default not triggered. A measurement is
triggered when the action is sent with the appropriate
function specified. One or more measurements may be triggered
while the Central Office (CO) Single Ended Line Test Physical
Medium Dependent (SELT-PMD) is configured 'enable', possibly
with different CO SELT-PMD configuration parameters. If the
triggered measurement cannot be executed, then the
Access Node (AN)/Distribution Point Unit (DPU) Maintenance
Entity (ME) rejects this action and the CO SELT-PMD status
remains 'inactive'.";
        input {
          leaf pmd-function {
            type union {
              type enumeration {
                enum "abort" {
                  value 0;
                  description
                    "Triggers the Central Office (CO) Single Ended Line
Test Physical Medium Dependent (SELT-PMD) to abort
any currently ongoing measurement.";
                }
              }
              type pmd-function;
            }
            description
              "The action being requested.";
          }
        }
      }  // rpc request-pmd-function-c
    }  // grouping pmd-control

    grouping co-cpe-parameters {
      description
        "Parameters to define the configuration common between the
Central Office (CO) CO Single Ended Line Test Physical Medium
Dependent (SELT-PMD) and Customer Premises Equipment (CPE)
SELT-PMD.";
      leaf uer-measurement-duration {
        type uer-measurement-duration;
        description
          "The Uncalibrated Echo Response (UER) duration for the
Single Ended Line Test Physical Medium Dependent
(SELT-PMD).";
        reference
          "ITU-T G.996.2 clause A.2.1.1 (SELT-UER-MMD-C,
          SELT-UER-MMD-R)";

      }

      leaf qln-measurement-duration {
        type qln-measurement-duration;
        description
          "The Quiet Line Noise(QLN) duration for the Single Ended Line
Test Physical Medium Dependent (SELT-PMD).";
        reference
          "ITU-T G.996.2 clause A.2.1.2 (SELT-QLN-MMD-C,
          SELT-QLN-MMD-R)";

      }
    }  // grouping co-cpe-parameters

    grouping pmd-profile {
      description
        "Defines the parameters contained in a Physical Medium Dependent
(PMD) profile.";
      container c {
        description
          "Managed objects applicable to the Central Office (CO) Single
Ended Line Test Physical Medium Dependent (SELT-PMD).";
        uses co-cpe-parameters;
      }  // container c

      container r {
        description
          "Managed objects applicable to the Customer Premises
Equipment (CPE) Single Ended Line Test Physical Medium
Dependent (SELT-PMD).";
        uses co-cpe-parameters;
      }  // container r
    }  // grouping pmd-profile

    grouping downstream-upstream-parameters {
      description
        "Parameters to define the configuration common between the
downstream and upstream directions";
      container capacity-estimate-signal-psd {
        description
          "This configuration parameter defines the Power Spectral
Density (PSD) template of the transmit signal to be used in
capacity estimate evaluation. The PSD template CAP-SIGNALPSD
shall be specified through a set of breakpoints. Each
breakpoint shall consist of a frequency index, tn, and a
signal PSD level (expressed in dBm/Hz). The parameter shall
be a set of breakpoints represented by [(t1, PSD1),
(t2, PSD2), ..., (tN, PSDN)], where t1 and tN represent,
respectively, the lower frequency of the lowest band over
which the capacity estimate is to be calculated, and the
highest frequency of highest band over which the capacity
estimate is to be calculated. In the case of an estimation of
capacity for a multi-band xDSL, the set of breakpoints shall
describe the stopbands situated inbetween passbands.

NOTE - Stopbands may be described as brickwall stopbands
       using the lowest valid value (-200 dBm/Hz) or may be
       described more elaborately.

The breakpoints shall be defined so that tn < tn+1 for n = 1
to N - 1. The frequency fn corresponding to the index tn can
be found as: fn = tn * Df. The value of Df = 4.3125 kHz and
is independent of the subcarrier spacing used for the DMT
modulation of the xDSL.

The range of valid values for index tn is 0 to 8191 in steps
of 1. The range of valid values for PSD is -30 to -200
dBm/Hz in steps of 0.1 dBm/Hz.

The maximum number of breakpoints in downstream is 48,
and in upstream 48.";
        reference
          "ITU-T G.996.2 clause B.2.1.2 (CAP-SIGNALPSD)";

        list psd {
          key "t";
          max-elements 48;
          description
            "A list of Power Spectral Density (PSD) values per
breakpoint, t.";
          leaf t {
            type uint16 {
              range "0..8191";
            }
            description
              "The breakpoint index.";
          }

          leaf psd {
            type int16 {
              range "-2000..-300";
            }
            units "0.1 dBm/Hz";
            mandatory true;
            description
              "The Power Spectral Density (PSD) value.";
          }
        }  // list psd
      }  // container capacity-estimate-signal-psd

      container capacity-estimate-noise-psd {
        description
          "This configuration parameter defines the Power Spectral
Density (PSD) template of the received noise to be used in
capacity estimate evaluation. The PSD template CAP-NOISEPSD
shall be specified through a set of breakpoints. Each
breakpoint shall consist of a frequency index tn and a signal
PSD level (expressed in dBm/Hz). The parameter shall be a set
of breakpoints that are represented by [(t1, PSD1),
(t2, PSD2), ... ,(tN, PSDN)], where t1 and tN are,
respectively, the lower frequency of the lowest band over
which the capacity estimate is to be calculated, and the
highest frequency of highest band over which the capacity
estimate is to be calculated.

In the case of an estimation of capacity for a multi-band
xDSL, with the CAP-SIGNALPSD stopbands described as
brickwall stopbands, the set of breakpoints for CAP-NOISEPSD
is not required to describe the noise in the stopbands
situated inbetween passbands. In case the CAP-SIGNALPSD
stopbands are not described as brickwall stopbands, the set
of breakpoints for CAP-NOISEPSD shall describe the noise in
the stopbands situated inbetween passbands. The breakpoints
shall be defined so that tn < tn+1 for n = 1 to N - 1. The
frequency fn corresponding to the index tn can be found as:
fn = tn * Df. The value of Df = 4.3125 kHz and is
independent of the subcarrier spacing used for the DMT
modulation of the xDSL.

The range of valid values for index tn is 0 to 8191, in
steps of 1. The range of valid values for PSD is -30 to -200
dBm/Hz, in steps of 0.1 dBm/Hz

The maximum number of breakpoints in downstream is 128, and
in upstream 128.";
        reference
          "ITU-T G.996.2 clause B.2.1.3 (CAP-NOISEPSD)";

        list psd {
          key "t";
          max-elements 128;
          description
            "A list of Power Spectral Density (PSD) values per
breakpoint, t.";
          leaf t {
            type uint16 {
              range "0..8191";
            }
            description
              "The breakpoint index.";
          }

          leaf psd {
            type int16 {
              range "-2000..-30";
            }
            units "0.1 dBm/Hz";
            mandatory true;
            description
              "The Power Spectral Density (PSD) value.";
          }
        }  // list psd
      }  // container capacity-estimate-noise-psd

      leaf capacity-estimate-target-noise-margin {
        type uint16 {
          range "0..310";
        }
        units "0.1 dB";
        description
          "This is the noise margin to be used in capacity estimate
evaluation, relative to a Bit Error Rate (BER) requirement
of 1E-7.

The range of valid values for CAP-TARSNRM expressed in dB is
0 to 31 dB, in steps of 0.1 dB";
        reference
          "ITU-T G.996.2 clause B.2.1.4 (CAP-TARSNRM)";

      }
    }  // grouping downstream-upstream-parameters

    grouping processing-profile {
      description
        "Defines the parameters contained in a processing profile.";
      leaf capacity-estimate-calculation-enabling {
        type boolean;
        description
          "This parameter specifies if the Single Ended Line Test
Processing (SELT-P) function shall perform the 'downstream
capacity' and 'upstream capacity' estimations, if supported.
This parameter is expressed as a boolean flag and takes the
value 'false' if xDSL performance estimation is not required,
true otherwise.";
        reference
          "ITU-T G.996.2 clause B.2.1.1 (CECE)";

      }

      container downstream {
        description
          "Data nodes applicable in the downstream direction.";
        uses downstream-upstream-parameters;
      }  // container downstream

      container upstream {
        description
          "Data nodes applicable in the upstream direction.";
        uses downstream-upstream-parameters;
      }  // container upstream
    }  // grouping processing-profile

    grouping pmd-status {
      description
        "Status parameters for the Physical Medium Dependent (PMD)
object.";
      leaf selt-status-c {
        type enumeration {
          enum "inactive" {
            value 0;
            description
              "The Central Office (CO) Single Ended Line Test Physical
Medium Dependent (SELT-PMD) is inactive.";
          }
          enum "uer-ongoing" {
            value 1;
            description
              "The Central Office (CO) Single Ended Line Test Physical
Medium Dependent (SELT-PMD) has an Uncalibrated Echo
Response (UER) measurement ongoing.";
          }
          enum "qln-ongoing" {
            value 2;
            description
              "The Central Office (CO) Single Ended Line Test Physical
Medium Dependent (SELT-PMD) has a Quiet Line Noise (QLN)
measurement ongoing.";
          }
        }
        description
          "The status of the Central Office (CO) Single Ended Line Test
Physical Medium Dependent (SELT-PMD) measurement.

Upon the CO SELT PMD request triggering a Uncalibrated Echo
Response (UER) measurement, the CO SELT PMD status shall
become 'uer-ongoing' if the measurement is executed.

Upon the CO SELT PMD request triggering a Quiet Line Noise
(QLN) measurement, the CO SELT PMD status shall become
'qln-ongoing' if the measurement is executed.

Upon abortion, failure or successful completion of the UER or
QLN measurement, the CO SELT PMD status shall become
'inactive' and the Access Node (AN)/Distribution Point Unit
(DPU) Management Entity (ME) shall send a notification to the
NMS.";
        reference
          "ITU-T G.996.2 clause A.3.3";

      }

      leaf uer-results-c {
        type pmd-result;
        description
          "The status of the Central Office (CO) Single Ended Line Test
Physical Medium Dependent (SELT-PMD) Uncalibrated Echo
Response (UER) measurement results.";
        reference
          "ITU-T G.996.2 clause A.3.4";

      }

      leaf qln-results-c {
        type pmd-result;
        description
          "The status of the Central Office (CO) Single Ended Line Test
Physical Medium Dependent (SELT-PMD) Quiet Line Noise (QLN)
measurement results.";
        reference
          "ITU-T G.996.2 clause A.3.5";

      }
    }  // grouping pmd-status

    grouping co-cpe-measurement-parameters {
      description
        "Defines the measurement parameters common between the Central
Office (CO) Single Ended Line Test Physical Medium Dependent
(SELT-PMD) and Customer Premises Equipment (CPE) SELT-PMD";
      container uncalibrated-echo-response {
        description
          "The Uncalibrated Echo Response, UER(i* UER_G*Df), shall be
represented in linear format by a scale factor and a
normalized complex number a(i)+j*b(i), where i is a frequency
index i ranging from 0 to NSC-1, the subcarrier spacing,
Df = 4.3125 kHz, and (NSC-1) x UER_G x Df is the highest
frequency supported by the SELT-PMD functionality.

The UER granularity parameter, UER_G, has three valid
values: 1, 2, and 12, indicating whether the measurements
were performed using a subcarrier spacing of 4.3125 kHz,
8.625 kHz, or 51.75 kHz respectively.

The scale factor shall be coded as a 32-bit unsigned integer.
Both a(i) and b(i) shall be coded as 32 bit 2's complement
signed integers. The value of UER(i* UER_G*Df) shall be
defined as:
  UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31.
In order to maximize precision, the scale factor shall be
chosen such that max(|a(i)|, |b(i)|) over all i is equal to
2^31-1.

NOTE - This data format supports an UER(f) granularity of
2-31 and an UER(f) dynamic range of approximately +6 dB to
-186 dB, however it does not imply any future accuracy
requirements.

An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is
a special value. It indicates that no measurement could be
done for this subcarrier either because it is not supported
by the Single Ended Line Test Physical Medium Dependent
(SELT-PMD) function, or that the value is out of range
to be represented.";
        reference
          "ITU-T G.996.2 clause A.2.2.1 (SELT-UER-C, SELT-UER-R)";

        leaf scale-factor {
          type uint32;
          description
            "The scale factor used in the Uncalibrated Echo Response
(UER) measurement";
        }

        leaf uer-g {
          type uint8 {
            range "1 | 2 | 12";
          }
          description
            "The Single Ended Line Test Uncalibrated Echo Response Group
size (SELT-UER_G) is a reported parameter identifying the
UER frequency spacing, which is equal to SELT-UER_G x Df
with Df = 4.3125 kHz. SELT-UER_G has three valid values:
1, 2, and 12. Section A.2.2.1 refers to SELT-UER_G as the
UER granularity parameter, UER_G.";
        }

        leaf uer {
          type per-sub-carrier-int32-tuple;
          description
            "An array of tuples representing the a(i) and b(i) values
as described below. In each tuple, a(i) is loaded first.";
          reference
            "ITU-T G.996.2 clause A.2.2.1 (SELT-UER-C, SELT-UER-R)";

        }
      }  // container uncalibrated-echo-response

      leaf uncalibrated-echo-response-variance {
        type per-sub-carrier-uint8;
        description
          "The REL_VAR_UER(f) provides the relative variance of the
uncalibrated echo response by the Single Ended Line Test
Physical Medium Dependent (SELT-PMD) function for each
frequency i * UER_G * Df, where i ranges from 0 to NSC-1,
Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the highest
frequency supported by the SELT-PMD functionality.

The relative variance of the uncalibrated echo response
REL_VAR_UER(i* UER_G *Df) shall be represented as an 8-bit
unsigned integer v(i), where i is the subcarrier index
i = 0 to NSC-1. The value of REL_VAR_UER(i* UER_G *Df) shall
be defined as REL_VAR_UER(i* UER_G *Df) = 3 - v(i)/2 dB.
The number v(i) is an 8-bit unsigned integer in the range 0
to 254. This data format supports a REL_VAR_UER(i) over a
range from -124 dB to +3 dB for each carrier with a
granularity from 0.5 dB. Out of range values shall be
clamped to the closest range bound. The special value v(i) =
255 indicates that no measurement is available for that
carrier.";
        reference
          "ITU-T G.996.2 clause A.2.2.2 (SELT-UER-VAR-C,
          SELT-UER-VAR-R)";

      }

      container quiet-line-noise {
        description
          "The Single Ended Line Test Quiet Line Noise (SELTQLN)
provides the quiet line noise Power Spectral Density (PSD)
as measured by the Single Ended Line Test Physical Medium
Dependent (SELT-PMD) function (see clause A.1.1.2) for
each sub-carrier frequency i x SELTQLN_G x Df where i ranges
from 0 to NSC-1, Df = 4.3125 kHz, and
(NSC-1) x SELTQLN_G x Df is the highest frequency supported
by the SELT-PMD functionality.

SELTQLN_G has three valid values: 1, 2, and 12, indicating
whether the measurements were performed using a subcarrier
spacing of 4.3125 kHz,  8.625 kHz, or of 51.75 kHz
respectively.

SELT quiet line noise SELTQLN(i x SELTQLN_G x Df) shall be
represented as an 8 bit unsigned integer n(i), where i is the
subcarrier index i = 0 to NSC-1. The value of
SELTQLN(i x SELTQLN_G x Df) shall be defined as
SELTQLN(i x SELTQLN_G x Df ) = -23 - (n(i)/2) dBm/Hz. This
data format supports a SELTQLN(f) granularity of 0.5 dB and
an SELTQLN(f) dynamic range of -150 to -23 dBm/Hz.";
        reference
          "ITU-T G.996.2 clause A.2.2.3 (SELT-QLN-C, SELT-QLN-R)";

        leaf seltqln-g {
          type uint8 {
            range "1 | 2 | 12";
          }
          description
            "The Single Ended Line Test Quiet Line Noise Group size
(SELTQLN_G) is a reported parameter identifying the
SELTQLN frequency spacing, which is equal to SELTQLN_G x Df
with Df = 4.3125 kHz. SELTQLN_G has three valid values:
1, 2, and 12.";
        }

        leaf qln {
          type per-sub-carrier-uint8;
          description
            "An array of values representing n(i).";
        }
      }  // container quiet-line-noise
    }  // grouping co-cpe-measurement-parameters

    grouping pmd-measurement-parameters {
      description
        "Defines the Single Ended Line Test Physical Medium Dependent
(SELT-PMD) measurement parameters.";
      container c {
        description
          "Parameters applicable to the Central Office (CO) Single Ended
Line Test Physical Medium Dependent (SELT-PMD).";
        uses co-cpe-measurement-parameters;
      }  // container c

      container r {
        description
          "Parameters applicable to the Customer Premises Equipment
(CPE) Single Ended Line Test Physical Medium Dependent
(SELT-PMD).";
        uses co-cpe-measurement-parameters;
      }  // container r
    }  // grouping pmd-measurement-parameters

    grouping downstream-upstream-derived-parameters {
      description
        "Derived parameters that are common between the downstream and
upstream directions";
      leaf capacity-estimate {
        type bbf-yang:data-rate32;
        description
          "This parameter represents a best-effort estimate of the
achievable net data rate (in kbit/s) on the loop under test,
under the following assumptions:

- Fast mode (i.e., operation with interleaver depth D=1, and
  INP=0 (no impulse noise protection))
- use of Trellis coding
- target margin equal to CAP-TARSNRM (see clause B.2.1.4)
- transmit signal PSD at the U-interface of the
  xTU-transmitter equal to CAP-SIGNALPSD
  (see clause B.2.1.2)
- noise PSD at the U-interface of the xTU-receiver equal to
  CAP-NOISEPSD (see clause B.2.1.3)
- support of bit loading from 1 to 15 bits included, in
  steps of 1 bit increments.

As the capacity is a best-effort estimate, accuracy for this
parameter is vendor proprietary. The parameter in the
downstream direction is CAPACITYds, and the parameter in the
upstream direction is CAPACITYus";
        reference
          "ITU-T G.996.2 clause B.2.2.7 (CAP-EST)";

      }
    }  // grouping downstream-upstream-derived-parameters

    grouping processing-derived-parameters {
      description
        "Defines the Single Ended Line Test Processing (SELT-P) derived
parameters.";
      leaf loop-termination-indicator {
        type enumeration {
          enum "open" {
            value 0;
            description "Open.";
          }
          enum "short" {
            value 1;
            description "Short.";
          }
          enum "powered-by-cpe" {
            value 2;
            description
              "Powered on Customer Premises Equipment (CPE).";
          }
          enum "unknown" {
            value 3;
            description
              "Unknown (i.e., failure in identifying the termination).";
          }
        }
        description
          "Loop termination indicator is a three state indication of
the loop termination defined as follows.

1) Open
2) Short
3) Powered on CPE
4) Unknown (i.e., failure in identifying the termination)";
        reference
          "ITU-T G.996.2 clause B.2.2.1 (LOOP-TERM)";

      }

      leaf loop-length {
        type uint16 {
          range "0..16383";
        }
        units "1 meter";
        description
          "This parameter is the physical length (in metres) of the
loop between the U-C and the U-R interface. The loop length
shall be measured with a granularity of 1 m, with valid
range of 0 to 16383 m.";
        reference
          "ITU-T G.996.2 clause B.2.2.2 (LOOP-LEN)";

      }

      container loop-topology {
        description
          "The loop topology consists of a description of the loop
structure, with indication of the physical length of each
loop segment. In this parameter, a loop segment is defined
as delimited by either a loop termination, or the presence
of a bridged tap.

NOTE 1 - Two cables with different gauges/cable-types
	 connected in series are considered as a single loop
	 segment.

The loop topology is reported as a list of loop segments,
using the following conventions:

1) The first loop segment in the list shall be the segment
   connected to the Single Ended Line Test Physical Medium
   Dependent (SELT-PMD) block measuring the SELT-PMD
   measurement parameters (i.e., the SELT-PMD block shall be
   the starting point of the topology description).
2) Subsequent loop segments in the list shall describe the
   loop in the direction toward the farend loop termination.
3) Consecutive loop segments indicated as 'bridged tap'
   represent bridged taps, each branching off from the main
   loop at the same point.

NOTE 2 - Identification of a bridged tap branching off on a
	 bridged tap is not supported by this parameter.
	 A single loop segment is specified with two
	 sub-parameters: loop segment length (see clause
	 B.1.1.3.1) and loop segment bridged tap indicator
	 (see clause B.1.1.3.2).

If this parameter is supported, reporting of up to three
segments is a mandatory capability. Reporting of additional
segments is optional. ";
        reference
          "ITU-T G.996.2 clause B.2.2.3 (LOOP-TOPOLOGY)";

        list loop {
          key "i";
          description
            "A list of loop segments including the length and whether
there is a bridged tap.";
          leaf i {
            type uint8;
            description
              "The segment number. The first loop segment in the list
shall be the segment connected to the Single Ended Line
Test Physical Medium Dependent (SELT-PMD) block measuring
the SELT-PMD measurement parameters (i.e., the
SELT-PMD block shall be the starting point of the
topology description). Subsequent loop segments in the
list shall describe the loop in the direction toward the
farend loop termination.";
          }

          leaf len {
            type uint16 {
              range "0..16383";
            }
            units "1 meter";
            description
              "This parameter specifies the physical length of the loop
segment, in metres. The loop segment length shall be
measured with a granularity of 1 m, with a valid range
of 0 to 16383 m.";
            reference
              "ITU-T G.996.2 clause B.1.1.3.1 (LOOP_SEGM_LENGTH)";

          }

          leaf bti {
            type enumeration {
              enum "in-series" {
                value 0;
                description "In series";
              }
              enum "bridged-tap" {
                value 1;
                description "Bridged tap";
              }
            }
            description
              "This parameter specifies whether the loop segment is a
bridged tap or arranged in series (i.e., not branching,
not a bridged tap).

The valid values are:

1) in series
2) bridged tap";
            reference
              "ITU-T G.996.2 clause B.1.1.3.1 (LOOP_SEGM_LENGTH)";

          }
        }  // list loop
      }  // container loop-topology

      container attenuation-characteristics {
        description
          "The line attenuation TFlog(f) is the logarithmic power
transfer function of the line as a function of frequency
when both the near-end and far-end line terminations have
the following values:

- Source impedance = purely resistive equal to 100 ohms
- Termination impedance = purely resistive equal to 100 ohms

The definition for reporting the line attenuation TFlog(f)
depends on whether or not the option for extended bandwidth
Single Ended Line Test (SELT) is applied.

The function TFlog(f) consists of an array of values
TFlog(i * TFlog_G * Df), with Df = 4.3125 kHz.

NOTE - In the case where the instantiation of the LT unit is
       the same as the instantiation of the xTU transceiver
       unit, this value may be independent of the subcarrier
       spacing used for the xDSL DMT modulation.

The range of valid values for the index i is 0 to 8191.

The attenuation characteristics group size, TFlog_G, has
three valid values: 1, 2, and 12, indicating whether the
measurements were performed using a subcarrier spacing of
4.3125 kHz, 8.625 kHz, or 51.75 kHz respectively.

The range of valid values for TFlog(i * Df) is from +6.0 dB
down to -96.2 dB, with a granularity of 0.1 dB (represented
as values 0 to 1022). A special value, 1023, is used to
indicate that no measurement could be done for this
subcarrier because the attenuation is out of the range that
can be represented.";
        reference
          "ITU-T G.996.2 clause B.2.2.6 (ATT-CHAR)";

        leaf tflog-g {
          type uint8 {
            range "1 | 2 | 12";
          }
          description
            "The attenuation characteristics group size (TFlog_G) is a
reported parameter identifying the attenuation
characteristics, TFlog(f), at a frequency spacing equal to
TFlog_G x Df with Df = 4.3125 kHz. TFlog_G has three valid
values: 1, 2, and 12.";
        }

        leaf tflog {
          type per-sub-carrier-uint16;
          description
            "An array of values for Tflog(f).";
        }
      }  // container attenuation-characteristics

      leaf missing-micro-filter {
        type boolean;
        description
          "This parameter is a binary indication of a missing or
incorrectly installed splitter or micro-filter at the U-R
reference point. A value of 1 for this flag represents a
missing splitter. This parameter is only defined for the
SELT-P-R functionality.";
        reference
          "ITU-T G.996.2 clause B.2.2.4 (MIS-FILTER)";

      }

      container downstream {
        description
          "Managed objects applicable in the downstream direction.";
        uses downstream-upstream-derived-parameters;
      }  // container downstream

      container upstream {
        description
          "Managed objects applicable in the upstream direction.";
        uses downstream-upstream-derived-parameters;
      }  // container upstream
    }  // grouping processing-derived-parameters

    // objects
    container selt {
      description
        "Single Ended Line Test (SELT) configuration.";
      container profiles {
        description
          "Configuration profiles.";
      }  // container profiles
    }  // container selt

    augment /if:interfaces/if:interface {
      when "if:type = 'ianaift:fastdsl'" {
        description
          "Only applicable when the interface type is 'fastdsl'";
      }
      description
        "Data nodes for the configuration of Single Ended Line Test
(SELT)";
      container selt {
        presence
          "If present, indicates that the interface is capable of
performing Single Ended Line Test (SELT) functionality as
defined in ITU-T G.996.2.";
        description
          "Configuration data for Single Ended Line Test (SELT).";
      }  // container selt
    }

    augment /if:interfaces-state/if:interface {
      when "if:type = 'ianaift:fastdsl'" {
        description
          "Only applicable when the interface type is 'fastdsl'";
      }
      description
        "Data nodes for the operational state data of Single Ended Line
Test (SELT)";
      container selt {
        presence
          "If present, indicates that the interface is capable of
performing Single Ended Line Test (SELT) functionality as
defined in ITU-T G.996.2.";
        description
          "Operational state data for Single Ended Line Test (SELT).";
      }  // container selt
    }

    augment /bbf-selt:selt/bbf-selt:profiles {
      description
        "Data nodes for Physical Medium Dependent (PMD) configuration
profiles.";
      list pmd-profile {
        key "name";
        description
          "A list of Physical Medium Dependent (PMD) profiles.";
        leaf name {
          type bbf-yang:string-ascii64;
          description
            "A name that uniquely identifies the profile.";
        }

        uses pmd-profile;
      }  // list pmd-profile
    }

    augment /bbf-selt:selt/bbf-selt:profiles {
      if-feature selt-p;
      description
        "Data nodes for processing profiles.";
      list processing-profile {
        key "name";
        description
          "A list of processing profiles.";
        leaf name {
          type bbf-yang:string-ascii64;
          description
            "A name that uniquely identifies the profile.";
        }

        uses processing-profile;
      }  // list processing-profile
    }

    augment /if:interfaces/if:interface/bbf-selt:selt {
      description
        "Data nodes to support the assignment of Single Ended Line Test
(SELT) configuration.";
      leaf pmd-profile {
        type pmd-profile-ref;
        status deprecated;
        description
          "References a Single Ended Line Test Physical Medium
Dependent (SELT-PMD) profile. This method of configuration
has been deprecated. The 'profile-config' method should
instead be used.";
      }

      leaf processing-profile {
        if-feature selt-p;
        type leafref {
          path "/bbf-selt:selt/bbf-selt:profiles/bbf-selt:processing-profile/bbf-selt:name";
        }
        status deprecated;
        description
          "References a Single Ended Line Test Processing (SELT-P)
profile. This method of configuration has been deprecated.
The 'profile-config' method should instead be used.";
      }

      container pmd-control {
        status deprecated;
        description
          "Data nodes to support the Single Ended Line Test Physical
Medium Dependent (SELT-PMD) control object";
        uses selt-pmd-control {
          status deprecated;
        }
      }  // container pmd-control

      choice profile-config {
        default "no-profiles-attached";
        description
          "Provides methods attachment of profiles.";
        leaf no-profiles-attached {
          type empty;
          description
            "If present, indicates that no profiles are attached
to this line";
        }
        container direct-attachment-mode {
          description
            "Configuration associated with assigning Single Ended Line
Test (SELT) profiles.";
          leaf pmd-profile {
            type pmd-profile-ref;
            mandatory true;
            description
              "References a Single Ended Line Test Physical Medium
Dependent (SELT-PMD) profile.";
          }

          leaf processing-profile {
            if-feature selt-p;
            type leafref {
              path "/bbf-selt:selt/bbf-selt:profiles/bbf-selt:processing-profile/bbf-selt:name";
            }
            mandatory true;
            description
              "References a Single Ended Line Test Processing (SELT-P)
profile.";
          }
        }  // container direct-attachment-mode
      }  // choice profile-config
    }

    augment /if:interfaces/if:interface/bbf-selt:selt/bbf-selt:profile-config/bbf-selt:direct-attachment-mode/bbf-selt:direct-attachment-mode {
      description
        "Data nodes for the configuration of Single Ended Line Test
Physical Medium Dependent (SELT-PMD) control.";
      container pmd-control {
        description
          "Data nodes to support the Single Ended Line Test
Physical Medium Dependent (SELT-PMD) control object";
        uses pmd-control;
      }  // container pmd-control
    }

    augment /if:interfaces-state/if:interface/bbf-selt:selt {
      description
        "Data nodes for the configuration of Single Ended Line Test
Physical Medium Dependent (SELT-PMD) status.";
      container pmd-status {
        description
          "Data nodes to support the Single Ended Line Test
Physical Medium Dependent (SELT-PMD) control object";
        uses pmd-status;
      }  // container pmd-status

      notification selt-pmd-completed {
        description
          "Indicates that a Single Ended Line Test Physical Medium
Dependent (SELT-PMD) function has failed, succeeded
or has been aborted.";
        leaf function {
          type pmd-function;
          mandatory true;
          description
            "The function that was performed or attempted to perform.";
        }

        leaf result {
          type pmd-result;
          mandatory true;
          description
            "The result of the attempted execution of the Single Ended
Line Test Physical Medium Dependent (SELT-PMD) function.";
        }
      }  // notification selt-pmd-completed
    }

    augment /if:interfaces-state/if:interface/bbf-selt:selt {
      description
        "Data nodes to support the reporting of SELT result
parameters.";
      container pmd-measurement-parameters {
        description
          "Single Ended Line Test Physical Medium Dependent (SELT-PMD)
measurement parameters.";
        uses pmd-measurement-parameters;
      }  // container pmd-measurement-parameters

      container processing-derived-parameters {
        if-feature selt-p;
        description
          "Single Ended Line Test Processing (SELT-P) derived
parameters.";
        uses processing-derived-parameters;
      }  // container processing-derived-parameters
    }
  }  // module bbf-selt

Summary

  
bbf-selt-processing-profile-body  
  
Organization Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area
  
Submodule bbf-selt-processing-profile-body
Version 2019-06-11
File bbf-selt-processing-profile-body.yang
  
  
Cooked /cookedmodules/bbf-selt-processing-profile-body/2019-06-11
YANG /src/bbf-selt-processing-profile-body@2019-06-11.yang
XSD /xsd/bbf-selt-processing-profile-body@2019-06-11.xsd
  
Abstract This submodule contains a collection of YANG definitions for managing processing profiles. Copyright (c) 2016-2019 Broadband Fo...
  
Contact
Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN
  
bbf-selt-pmd-profile-body  
  
Organization Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area
  
Submodule bbf-selt-pmd-profile-body
Version 2019-06-11
File bbf-selt-pmd-profile-body.yang
  
  
Cooked /cookedmodules/bbf-selt-pmd-profile-body/2019-06-11
YANG /src/bbf-selt-pmd-profile-body@2019-06-11.yang
XSD /xsd/bbf-selt-pmd-profile-body@2019-06-11.xsd
  
Abstract This submodule contains a collection of YANG definitions for managing Physical Medium Dependent (PMD) profiles. Copyright (c) 2...
  
Contact
Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN
  
bbf-selt-pmd-profiles  
  
Organization Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area
  
Submodule bbf-selt-pmd-profiles
Version 2019-06-11
File bbf-selt-pmd-profiles.yang
  
  
Cooked /cookedmodules/bbf-selt-pmd-profiles/2019-06-11
YANG /src/bbf-selt-pmd-profiles@2019-06-11.yang
XSD /xsd/bbf-selt-pmd-profiles@2019-06-11.xsd
  
Abstract This submodule contains a collection of YANG definitions for managing SELT-PMD profiles. Copyright (c) 2016-2019 Broadband Foru...
  
Contact
Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN
  
bbf-selt  
  
Organization Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area
  
Module bbf-selt
Version 2019-06-11
File bbf-selt.yang
  
Prefix bbf-selt
Namespace urn:bbf:yang:bbf-selt
  
Cooked /cookedmodules/bbf-selt/2019-06-11
YANG /src/bbf-selt@2019-06-11.yang
XSD /xsd/bbf-selt@2019-06-11.xsd
  
Abstract This module contains a collection of YANG definitions for supporting Single Ended Line Test (SELT) as defined in ITU G.996.2. C...
  
Contact
Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN
  
bbf-selt-pmd  
  
Organization Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area
  
Submodule bbf-selt-pmd
Version 2019-06-11
File bbf-selt-pmd.yang
  
  
Cooked /cookedmodules/bbf-selt-pmd/2019-06-11
YANG /src/bbf-selt-pmd@2019-06-11.yang
XSD /xsd/bbf-selt-pmd@2019-06-11.xsd
  
Abstract This submodule contains a collection of YANG definitions for managing the Physical Medium Dependent (PMD) object. Copyright (c)...
  
Contact
Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN
  
bbf-selt-pmd-measurement-parameter-body  
  
Organization Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area
  
Submodule bbf-selt-pmd-measurement-parameter-body
Version 2019-06-11
File bbf-selt-pmd-measurement-parameter-body.yang
  
  
Cooked /cookedmodules/bbf-selt-pmd-measurement-parameter-body/2019-06-11
YANG /src/bbf-selt-pmd-measurement-parameter-body@2019-06-11.yang
XSD /xsd/bbf-selt-pmd-measurement-parameter-body@2019-06-11.xsd
  
Abstract This submodule contains a collection of YANG definitions for Single Ended Line Test Physical Medium Dependent (SELT-PMD) measure...
  
Contact
Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN
  
bbf-selt-processing-derived-parameter-body  
  
Organization Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area
  
Submodule bbf-selt-processing-derived-parameter-body
Version 2019-06-11
File bbf-selt-processing-derived-parameter-body.yang
  
  
Cooked /cookedmodules/bbf-selt-processing-derived-parameter-body/2019-06-11
YANG /src/bbf-selt-processing-derived-parameter-body@2019-06-11.yang
XSD /xsd/bbf-selt-processing-derived-parameter-body@2019-06-11.xsd
  
Abstract This submodule contains a collection of YANG definitions for Single Ended Line Test Processing (SELT-P) derived parameters. Cop...
  
Contact
Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN
  
bbf-selt-base  
  
Organization Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area
  
Submodule bbf-selt-base
Version 2019-06-11
File bbf-selt-base.yang
  
  
Cooked /cookedmodules/bbf-selt-base/2019-06-11
YANG /src/bbf-selt-base@2019-06-11.yang
XSD /xsd/bbf-selt-base@2019-06-11.xsd
  
Abstract This submodule contains a collection of YANG definitions for managing top level Single Ended Line Test (SELT) configuration and ...
  
Contact
Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN
  
bbf-selt-pmd-control-body  
  
Organization Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area
  
Submodule bbf-selt-pmd-control-body
Version 2019-06-11
File bbf-selt-pmd-control-body.yang
  
  
Cooked /cookedmodules/bbf-selt-pmd-control-body/2019-06-11
YANG /src/bbf-selt-pmd-control-body@2019-06-11.yang
XSD /xsd/bbf-selt-pmd-control-body@2019-06-11.xsd
  
Abstract This submodule contains a collection of YANG definitions for managing the Physical Medium Dependet (PMD) control object. Copyri...
  
Contact
Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN
  
bbf-selt-processing-profiles  
  
Organization Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area
  
Submodule bbf-selt-processing-profiles
Version 2019-06-11
File bbf-selt-processing-profiles.yang
  
  
Cooked /cookedmodules/bbf-selt-processing-profiles/2019-06-11
YANG /src/bbf-selt-processing-profiles@2019-06-11.yang
XSD /xsd/bbf-selt-processing-profiles@2019-06-11.xsd
  
Abstract This submodule contains a collection of YANG definitions for managing SELT-P profiles. Copyright (c) 2016-2019 Broadband Forum ...
  
Contact
Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN
  
bbf-selt-pmd-status-body  
  
Organization Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area
  
Submodule bbf-selt-pmd-status-body
Version 2019-06-11
File bbf-selt-pmd-status-body.yang
  
  
Cooked /cookedmodules/bbf-selt-pmd-status-body/2019-06-11
YANG /src/bbf-selt-pmd-status-body@2019-06-11.yang
XSD /xsd/bbf-selt-pmd-status-body@2019-06-11.xsd
  
Abstract This submodule contains a collection of YANG definitions for managing the Physical Medium Dependent (PMD) object. Copyright (c)...
  
Contact
Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN
  
bbf-selt-result-parameters  
  
Organization Broadband Forum <https://www.broadband-forum.org> Common YANG Work Area
  
Submodule bbf-selt-result-parameters
Version 2019-06-11
File bbf-selt-result-parameters.yang
  
  
Cooked /cookedmodules/bbf-selt-result-parameters/2019-06-11
YANG /src/bbf-selt-result-parameters@2019-06-11.yang
XSD /xsd/bbf-selt-result-parameters@2019-06-11.xsd
  
Abstract This submodule contains a collection of YANG definitions for managing Single Ended Line Test (SELT) result parameters. Copyrigh...
  
Contact
Comments or questions about this Broadband Forum YANG module
should be directed to <mailto:help@broadband-forum.org>.

Editor:      Ken Kerpez, ASSIA, Inc.

Editor:      Joey Boyd, ADTRAN

PS Leader:   Ken Kerpez, ASSIA, Inc.

PS Leader:   Joey Boyd, ADTRAN

WA Director: Sven Ooghe, Nokia

WA Director: Joey Boyd, ADTRAN

Description

 
bbf-selt-processing-profile-body
This submodule contains a collection of YANG definitions for
managing processing profiles.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.
 
bbf-selt-pmd-profile-body
This submodule contains a collection of YANG definitions for
managing Physical Medium Dependent (PMD) profiles.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.
 
bbf-selt-pmd-profiles
This submodule contains a collection of YANG definitions for
managing SELT-PMD profiles.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.
 
bbf-selt
This module contains a collection of YANG definitions for
supporting Single Ended Line Test (SELT) as defined in ITU
G.996.2.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.
 
bbf-selt-pmd
This submodule contains a collection of YANG definitions for
managing the Physical Medium Dependent (PMD) object.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.
 
bbf-selt-pmd-measurement-parameter-body
This submodule contains a collection of YANG definitions for
Single Ended Line Test Physical Medium Dependent (SELT-PMD)
measurement parameters.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.
 
bbf-selt-processing-derived-parameter-body
This submodule contains a collection of YANG definitions for
Single Ended Line Test Processing (SELT-P) derived parameters.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.
 
bbf-selt-base
This submodule contains a collection of YANG definitions for
managing top level Single Ended Line Test (SELT) configuration
and augmenations to ietf-interfaces.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.
 
bbf-selt-pmd-control-body
This submodule contains a collection of YANG definitions for
managing the Physical Medium Dependet (PMD) control object.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.
 
bbf-selt-processing-profiles
This submodule contains a collection of YANG definitions for
managing SELT-P profiles.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.
 
bbf-selt-pmd-status-body
This submodule contains a collection of YANG definitions for
managing the Physical Medium Dependent (PMD) object.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.
 
bbf-selt-result-parameters
This submodule contains a collection of YANG definitions for
managing Single Ended Line Test (SELT) result parameters.

Copyright (c) 2016-2019 Broadband Forum

Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the following
conditions are met:

1. Redistributions of source code must retain the above copyright
   notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above
   copyright notice, this list of conditions and the following
   disclaimer in the documentation and/or other materials
   provided with the distribution.

3. Neither the name of the copyright holder nor the names of its
   contributors may be used to endorse or promote products
   derived from this software without specific prior written
   permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

The above license is used as a license under copyright only.
Please reference the Forum IPR Policy for patent licensing terms
<https://www.broadband-forum.org/ipr-policy>.

Any moral rights which are necessary to exercise under the above
license grant are also deemed granted under this license.

This version of this YANG module is part of TR-355a2; see
the TR itself for full legal notices.

Typedefs

Typedef Base type Abstract
per-sub-carrier-int32-tuple binary A binary type where each group of 8 octets represents a tuple. A tuple consists of two 4-octet groups and represents data belonging to a sub-carrier. The first tuple represents sub-carrier group 0 and the last tuple represents sub-carrier group (length/8 ...
per-sub-carrier-uint16 binary A binary type where each pair of octets represents data belonging to a sub-carrier group. The first pair represents sub-carrier group 0 and the last represents sub-carrier group (length/2 - 1).
per-sub-carrier-uint8 binary A binary type where each octet represents data belonging to a sub-carrier group. The first octet represents sub-carrier group 0 and the last octet represents the sub-carrier group (length - 1).
pmd-function enumeration The Central Office (CO) Single Ended Line Test Physical Medium Dependent (SELT-PMD) function.
pmd-profile-ref leafref Used to reference a Physical Medium Dependent (PMD) profile.
pmd-result enumeration The overall results of the SELT PMD measurement.
qln-measurement-duration uint8 This parameter is the maximum allowed time for Singe Ended Line Test (SELT) Quiet Line Noise (QLN) measurement, between the time of the start command written by the Single Ended Line Test Physical Medium Dependent Management Entity (SELT-PMD-ME), and the ...
sub-carrier-index uint16 Identifies a sub-carrier.
uer-measurement-duration uint8 This parameter is the maximum allowed time for Singe Ended Line Test (SELT) Uncalibrated Echo Response (UER) measurement, between the time of the start command written by the Single Ended Line Test Physical Medium Dependent Management Entity (SELT-PMD-ME)...

Groupings

Grouping Objects Abstract
co-cpe-measurement-parameters uncalibrated-echo-response uncalibrated-echo-response-variance quiet-line-noise Defines the measurement parameters common between the Central Office (CO) Single Ended Line Test Physical Medium Dependent (SELT-PMD) and Customer Premises Equipment (CPE) SELT-PMD
co-cpe-parameters uer-measurement-duration qln-measurement-duration Parameters to define the configuration common between the Central Office (CO) CO Single Ended Line Test Physical Medium Dependent (SELT-PMD) and Customer Premises Equipment (CPE) SELT-PMD.
downstream-upstream-derived-parameters capacity-estimate Derived parameters that are common between the downstream and upstream directions
downstream-upstream-parameters capacity-estimate-signal-psd capacity-estimate-noise-psd capacity-estimate-target-noise-margin Parameters to define the configuration common between the downstream and upstream directions
pmd-control pmd-control request-pmd-function-c Physical Medium Dependent (PMD) control configuration.
pmd-measurement-parameters c r Defines the Single Ended Line Test Physical Medium Dependent (SELT-PMD) measurement parameters.
pmd-profile c r Defines the parameters contained in a Physical Medium Dependent (PMD) profile.
pmd-status selt-status-c uer-results-c qln-results-c Status parameters for the Physical Medium Dependent (PMD) object.
processing-derived-parameters loop-termination-indicator loop-length loop-topology attenuation-characteristics missing-micro-filter downstream upstream Defines the Single Ended Line Test Processing (SELT-P) derived parameters.
processing-profile capacity-estimate-calculation-enabling downstream upstream Defines the parameters contained in a processing profile.
selt-pmd-control uer-measurement-enable-c qln-measurement-enable-c Defines the parameters contained in the PMD control object.

Objects

Type Key
Mandatory config
Optional config
Not config
Object Type Abstract
selt container Single Ended Line Test (SELT) configuration.