ietf-interface-protection

This is a module for the entities in a generic interface protection mechanism. Copyright (c) 2019 IETF Trust and the persons id...

  • Version: 2019-06-19

    ietf-interface-protection@2019-06-19


    
      module ietf-interface-protection {
    
        yang-version 1.1;
    
        namespace
          "urn:ietf:params:xml:ns:yang:ietf-interface-protection";
    
        prefix ifprot;
    
        import ietf-interfaces {
          prefix if;
          reference
            "RFC 8343";
    
    
        }
    
        organization
          "Internet Engineering Task Force (IETF) CCAMP WG";
    
        contact
          "WG List: <mailto:ccamp@ietf.org>
    
    Editors:
     Jonas Ahlberg (jonas.ahlberg@ericsson.com)
     Min Ye (amy.yemin@huawei.com)
     Xi Li (Xi.Li@neclab.eu)
     Daniela Spreafico (daniela.spreafico@nokia.com)
     Marko Vaupotic (Marko.Vaupotic@aviatnet.com)";
    
        description
          "This is a module for the entities in
    a generic interface protection mechanism.
    
    Copyright (c) 2019 IETF Trust and the persons identified as
    authors of the code.  All rights reserved.
    
    Redistribution and use in source and binary forms, with or
    without modification, is permitted pursuant to, and subject
    to the license terms contained in, the Simplified BSD License
    set forth in Section 4.c of the IETF Trust's Legal Provisions
    Relating to IETF Documents
    (http://trustee.ietf.org/license-info).
    
    This version of this YANG module is part of RFC 8561; see
    the RFC itself for full legal notices.";
    
        revision "2019-06-19" {
          description "Initial revision.";
          reference
            "RFC 8561: A YANG Data Model for Microwave Radio Link";
    
        }
    
    
        identity protection-architecture-type {
          description
            "protection architecture type";
          reference
            "ITU-T G.808.1";
    
        }
    
        identity one-plus-one-type {
          base protection-architecture-type;
          description
            "1+1; one interface protects
    another one interface.";
          reference
            "ITU-T G.808.1";
    
        }
    
        identity one-to-n-type {
          base protection-architecture-type;
          description
            "1:N; one interface protects
    n other interfaces.";
          reference
            "ITU-T G.808.1";
    
        }
    
        identity protection-states {
          description
            "Identities describing the status of the protection
    in a group of interfaces configured in
    a protection mode.";
        }
    
        identity unprotected {
          base protection-states;
          description "Not protected.";
        }
    
        identity protected {
          base protection-states;
          description "Protected.";
        }
    
        identity unable-to-protect {
          base protection-states;
          description "Unable to protect.";
        }
    
        grouping protection-groups {
          description
            "Configuration of protected groups of interfaces
    providing protection for each other.  More than one
    protected group per higher-layer interface is allowed.";
          list protection-group {
            key "name";
            description
              "List of protected groups of interfaces
    in a higher-layer interface.";
            leaf name {
              type string;
              description
                "Name used for identification of the protection group.";
            }
    
            leaf protection-architecture-type {
              type identityref {
                base protection-architecture-type;
              }
              default "ifprot:one-plus-one-type";
              description
                "The type of protection architecture used, e.g., one
    interface protecting one or several other interfaces.";
              reference
                "ITU-T G.808.1";
    
            }
    
            leaf-list members {
              type if:interface-ref;
              min-elements 2;
              description
                "Association to a group of interfaces configured for
    protection and used by a higher-layer interface.";
            }
    
            leaf operation-type {
              type enumeration {
                enum "non-revertive" {
                  value 0;
                  description
                    "In non-revertive operation, the traffic does not
    return to the working interface if the switch requests
    are terminated.";
                  reference
                    "ITU-T G.808.1";
    
                }
                enum "revertive" {
                  value 1;
                  description
                    "In revertive operation, the traffic always
    returns to (or remains on) the working interface
    if the switch requests are terminated.";
                  reference
                    "ITU-T G.808.1";
    
                }
              }
              default "non-revertive";
              description
                "The type of protection operation, i.e., revertive
    or non-revertive operation.";
            }
    
            leaf-list working-entity {
              when
                "../operation-type = 'revertive'";
              type if:interface-ref;
              min-elements 1;
              description
                "The interfaces that the traffic normally should
    be transported over when there is no need to use the
    protecting interface.";
            }
    
            leaf revertive-wait-to-restore {
              when
                "../operation-type = 'revertive'";
              type uint16;
              units "seconds";
              default "0";
              description
                "The time to wait before switching back to the working
    interface if operation-type is revertive.";
              reference
                "ITU-T G.808.1";
    
            }
    
            leaf hold-off-timer {
              type uint16;
              units "milliseconds";
              default "0";
              description
                "Time interval after the detection of a fault and its
    confirmation as a condition requiring the protection-
    switching procedure.";
              reference
                "ITU-T G.808.1";
    
            }
    
            leaf status {
              type identityref {
                base protection-states;
              }
              config false;
              description
                "Status of the protection in a group of interfaces
    configured in a protection mode.";
              reference
                "ITU-T G.808.1";
    
            }
    
            action manual-switch-working {
              description
                "A switch action initiated by an operator command.
    It switches a normal traffic signal to the working
    transport entity.";
              reference
                "ITU-T G.808.1";
    
            }  // rpc manual-switch-working
    
            action manual-switch-protection {
              description
                "A switch action initiated by an operator command.
    It switches a normal traffic signal to the protection
    transport entity.";
              reference
                "ITU-T G.808.1";
    
            }  // rpc manual-switch-protection
    
            action forced-switch {
              description
                "A switch action initiated by an operator command.
    It switches a normal traffic signal to the protection
    transport entity and forces it to remain on that
    entity even when criteria for switching back to
    the original entity are fulfilled.";
              reference
                "ITU-T G.808.1";
    
            }  // rpc forced-switch
    
            action lockout-of-protection {
              description
                "A switch action temporarily disables access to the
    protection transport entity for all signals.";
              reference
                "ITU-T G.808.1";
    
            }  // rpc lockout-of-protection
    
            action freeze {
              description
                "A switch action temporarily prevents any switch action
    to be taken and, as such, freezes the current state.
    Until the freeze is cleared, additional near-end external
    commands are rejected, and fault condition changes and
    received Automatic Protection-Switching (APS) messages
    are ignored.";
              reference
                "ITU-T G.808.1";
    
            }  // rpc freeze
    
            action exercise {
              description
                "A switch action to test if the APS communication is
    operating correctly.  It is lower priority than any 'real'
    switch request.";
              reference
                "ITU-T G.808.1";
    
            }  // rpc exercise
    
            action clear {
              description
                "An action clears all switch commands.";
              reference
                "ITU-T G.808.1";
    
            }  // rpc clear
          }  // list protection-group
        }  // grouping protection-groups
      }  // module ietf-interface-protection
    

© 2023 YumaWorks, Inc. All rights reserved.