openconfig-alarms

This module defines operational state data related to alarms that the device is reporting. This model reuses some data items def...

  • Version: 2019-07-09

    openconfig-alarms@2019-07-09


    
      module openconfig-alarms {
    
        yang-version 1;
    
        namespace
          "http://openconfig.net/yang/alarms";
    
        prefix oc-alarms;
    
        import openconfig-alarm-types {
          prefix oc-alarm-types;
        }
        import openconfig-extensions {
          prefix oc-ext;
        }
        import openconfig-types {
          prefix oc-types;
        }
        import openconfig-platform {
          prefix oc-platform;
        }
    
        organization "OpenConfig working group";
    
        contact
          "OpenConfig working group
    www.openconfig.net";
    
        description
          "This module defines operational state data related to alarms
    that the device is reporting.
    
    This model reuses some data items defined in the draft IETF
    YANG Alarm Module:
    https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02
    
    Portions of this code were derived from the draft IETF YANG Alarm
    Module. Please reproduce this note if possible.
    
    IETF code is subject to the following copyright and license:
    Copyright (c) IETF Trust and the persons identified as authors of
    the code.
    All rights reserved.
    
    Redistribution and use in source and binary forms, with or without
    modification, is permitted pursuant to, and subject to the license
    terms contained in, the Simplified BSD License set forth in
    Section 4.c of the IETF Trust's Legal Provisions Relating
    to IETF Documents (http://trustee.ietf.org/license-info).";
    
        revision "2019-07-09" {
          description
            "Clarify relative base for leaves using timeticks64.";
          reference
            "0.3.2";
    
        }
    
        revision "2018-11-21" {
          description
            "Add OpenConfig module metadata extensions.";
          reference
            "0.3.1";
    
        }
    
        revision "2018-01-16" {
          description
            "Moved alarm identities into separate types module";
          reference
            "0.3.0";
    
        }
    
        revision "2018-01-10" {
          description
            "Make alarms list read only";
          reference
            "0.2.0";
    
        }
    
        revision "2017-08-24" {
          description "Initial public release";
          reference
            "0.1.0";
    
        }
    
        oc-ext:openconfig-version "0.3.2";
        oc-ext:regexp-posix;
        oc-ext:catalog-organization "openconfig";
        oc-ext:origin "openconfig";
    
        grouping alarm-state {
          description
            "Operational state data for device alarms";
          leaf id {
            type string;
            description
              "Unique ID for the alarm -- this will not be a
    configurable parameter on many implementations";
          }
    
          leaf resource {
            type string;
            description
              "The item that is under alarm within the device. The
    resource may be a reference to an item which is
    defined elsewhere in the model. For example, it
    may be a platform/component, interfaces/interface,
    terminal-device/logical-channels/channel, etc. In this
    case the system should match the name of the referenced
    item exactly. The referenced item could alternatively be
    the path of the item within the model.";
            reference
              "IETF YANG Alarm Module: Draft - typedef resource
              https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02";
    
          }
    
          leaf text {
            type string;
            description
              "The string used to inform operators about the alarm. This
    MUST contain enough information for an operator to be able
    to understand the problem. If this string contains structure,
    this format should be clearly documented for programs to be
    able to parse that information";
            reference
              "IETF YANG Alarm Module: Draft - typedef alarm-text
              https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02";
    
          }
    
          leaf time-created {
            type oc-types:timeticks64;
            description
              "The time at which the alarm was raised by the system.
    This value is expressed relative to the Unix Epoch.";
          }
    
          leaf severity {
            type identityref {
              base oc-alarm-types:OPENCONFIG_ALARM_SEVERITY;
            }
            description
              "The severity level indicating the criticality and impact
    of the alarm";
            reference
              "IETF YANG Alarm Module: Draft - typedef severity
              https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02";
    
          }
    
          leaf type-id {
            type union {
              type string;
              type identityref {
                base oc-alarm-types:OPENCONFIG_ALARM_TYPE_ID;
              }
            }
            description
              "The abbreviated name of the alarm, for example LOS,
    EQPT, or OTS. Also referred to in different systems as
    condition type, alarm identifier, or alarm mnemonic. It
    is recommended to use the OPENCONFIG_ALARM_TYPE_ID
    identities where possible and only use the string type
    when the desired identityref is not yet defined";
            reference
              "IETF YANG Alarm Module: Draft - typedef alarm-type-id
              https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02";
    
          }
        }  // grouping alarm-state
    
        grouping alarm-config {
          description
            "Configuration data for device alarms";
        }  // grouping alarm-config
    
        grouping alarms-top {
          description
            "Top-level grouping for device alarms";
          container alarms {
            config false;
            description
              "Top-level container for device alarms";
            list alarm {
              key "id";
              description
                "List of alarms, keyed by a unique id";
              leaf id {
                type leafref {
                  path "../state/id";
                }
                description
                  "References the unique alarm id";
              }
    
              container config {
                description
                  "Configuration data for each alarm";
                uses alarm-config;
              }  // container config
    
              container state {
                config false;
                description
                  "Operational state data for a device alarm";
                uses alarm-config;
    
                uses alarm-state;
              }  // container state
            }  // list alarm
          }  // container alarms
        }  // grouping alarms-top
    
        augment /oc-platform:components/oc-platform:component/oc-platform:state {
          description
            "Adds specific alarms related to a component.";
          leaf equipment-failure {
            type boolean;
            default "false";
            description
              "If true, the hardware indicates that the component's physical equipment
    has failed";
          }
    
          leaf equipment-mismatch {
            type boolean;
            default "false";
            description
              "If true, the hardware indicates that the component inserted into the
    affected component's physical location is of a different type than what
    is configured";
          }
        }
      }  // module openconfig-alarms
    

© 2023 YumaWorks, Inc. All rights reserved.