bbf-xponani

This module contains a collection of YANG definitions for supporting the Broadband Forum requirements on management of ITU-T Pas...

  • Version: 2020-10-13

    bbf-xponani@2020-10-13


    
      module bbf-xponani {
    
        yang-version 1.1;
    
        namespace "urn:bbf:yang:bbf-xponani";
    
        prefix bbf-xponani;
    
        include bbf-xponani-base;
        include bbf-xponani-ani-body;
        include bbf-xponani-v-enet-body;
    
        organization
          "Broadband Forum <https://www.broadband-forum.org>
         Fiber Access Networks Work Area";
    
        contact
          "Comments or questions about this Broadband Forum YANG module
         should be directed to <mailto:info@broadband-forum.org>.
    
         Editor:      Joey Boyd, ADTRAN
    
         Editor:      Igor Ternovsky, Broadcom
    
         Editor:      Robert Peschi, Nokia
    
         WA Director: Marta Seda, Calix
    
         WA Director: Samuel Chen, Broadcom";
    
        description
          "This module contains a collection of YANG definitions for
         supporting the Broadband Forum requirements on management of
         ITU-T Passive Optical Network (PON) interfaces as defined in
         ITU-T G.984.x, G.987.x, ITU-T G.989.x and ITU-T G.9807.x. As
         such, this module is specific to access network equipment (e.g.,
         BBF-specified Access Nodes and FTTdp DPUs).
    
         Specifically, this module defines management of Access Network
         Interfaces (ANI) which represent the physical Optical Network
         Unit (ONU).
    
         Copyright (c) 2018-2020, Broadband Forum
    
         Redistribution and use in source and binary forms, with or
         without modification, are permitted provided that the following
         conditions are met:
    
         1. Redistributions of source code must retain the above copyright
            notice, this list of conditions and the following disclaimer.
    
         2. Redistributions in binary form must reproduce the above
            copyright notice, this list of conditions and the following
            disclaimer in the documentation and/or other materials
            provided with the distribution.
    
         3. Neither the name of the copyright holder nor the names of its
            contributors may be used to endorse or promote products
            derived from this software without specific prior written
            permission.
    
         THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
         CONTRIBUTORS \"AS IS\" AND ANY EXPRESS OR IMPLIED WARRANTIES,
         INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
         MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
         DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
         CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
         SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
         NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
         LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
         CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
         STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
         ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
         ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
    
         The above license is used as a license under copyright only.
         Please reference the Forum IPR Policy for patent licensing terms
         <https://www.broadband-forum.org/ipr-policy>.
    
         Any moral rights which are necessary to exercise under the above
         license grant are also deemed granted under this license.
    
         This version of this YANG module is part of TR-385i2; see
         the TR itself for full legal notices.";
    
        revision "2020-10-13" {
          description
            "Issue 2.
           * Approval Date:    2020-10-13.
           * Publication Date: 2020-10-13.";
          reference
            "TR-385i2: ITU-T PON YANG Modules
            	<https://www.broadband-forum.org/technical/download/
            		 TR-385_Issue-2.pdf>";
    
        }
    
        revision "2019-02-25" {
          description
            "Initial revision.
           * Approval Date:    2019-02-25.
           * Publication Date: 2019-02-25.";
          reference
            "TR-385: ITU-T PON YANG Modules
            	<https://www.broadband-forum.org/technical/download/
            		 TR-385.pdf>";
    
        }
    
    
        // features
    
        feature configurable-ani-onu-id {
          description
            "Indicates support for configuration of the Optical Network Unit
    (ONU) ID associated with the Access Network Interface (ANI).";
        }
    
        feature configurable-ani-management-gem-port-id {
          description
            "Indicates support for configuration of the management
    G-PON Encapsulation Method (GEM) port.";
        }
    
        feature ani-onu-serial-number-reporting {
          description
            "Indicates that the Access Network Interface (ANI) holds the
    Optical Network Unit (ONU) serial number in its state data.";
        }
    
        feature ani-defects {
          description
            "Indicates support for reporting defects observed at the Access
    Network Interface (ANI).";
        }
    
        // groupings
        grouping ani-config-data {
          description
            "Configuration data intended for the Optical Network Unit (ONU)
    physical device. This data is brought to the ONU, when present,
    for instance via the Physical Layer Operations, Administrations
    and Maintenance (PLOAM) channel or using ONU Management and
    Control Interface (OMCI) on the Management G-PON Encapsulation
    Method (GEM) port.";
          leaf upstream-fec {
            type boolean;
            default "false";
            description
              "Enable/Disable use of Forward Error Correction (FEC) in the
    upstream direction for this specific Optical Network Unit
    (ONU).";
            reference
              "ITU-T G.984.3 clause 13.3.1.1
              ITU-T G.987.3 clause 10.2
              ITU-T G.9807.1 clause C.10.1.3.2.4
              ITU-T G.989.3 clause 10.1.3.2.4";
    
          }
    
          leaf management-gemport-aes-indicator {
            type boolean;
            default "false";
            description
              "Used to designate whether Advanced Encryption Standard
    (AES) should be enabled/disabled for the management G-PON
    Encapsulation Method (GEM) port of this Optical Network Unit
    (ONU).
    
    For G-PON, this applies in the downstream direction. For
    XG-PON, XGS-PON and NG-PON2, this applies to both the
    upstream and downstream directions.";
            reference
              "ITU-T G.984.3 section 12.1
              ITU-T G.987.3 section 15.5.1
              ITU-T G.9807.1 clause C.15.5.1
              ITU-T G.989.3 clause 15.5.1.";
    
          }
    
          leaf onu-id {
            if-feature bbf-xponani:configurable-ani-onu-id;
            type bbf-xpon-types:onu-id;
            description
              "This is the TC layer ONU-ID identifier. When configured this
    is the value which the Optical Line Termination (OLT) must
    assign to the Optical Network Unit (ONU) during the ONU's
    activation using the Assign_ONU-ID Physical Layer Operations,
    Administrations and Maintenance (PLOAM) message. For G-PON
    the value should be in [0..253], for XG-PON it should be in
    [0..1022] and for XGS-PON and NG-PON2 it should be in
    [0..1020].";
            reference
              "ITU-T G.984.3 clause 5.5.2
              ITU-T G.987.3 clause 6.4.2
              ITU-T G.9807.1 clause C.6.1.5.6
              ITU-T G.989.3 clause 6.1.5.6";
    
          }
    
          leaf management-gemport-id {
            if-feature bbf-xponani:configurable-ani-management-gem-port-id;
            type uint32;
            description
              "This leaf is only relevant to GPON ONUs; it is ignored for
    non-GPON ONUs. In contrast with other xPON technologies, in
    the case of G-PON, there is no requirement that the ITU-T TC
    ID of the management G-PON Encapsulation Method (GEM) port
    for the Optical Network Unit (ONU) is numerically equal to
    the ONU-ID. This leaf provides the capability to specify
    value for the management GEM port ID.
    
    If this leaf is not configured the management GEM port
    ID must be numerically equal to the ONU-ID.";
            reference
              "Refer to 'OMCC Port-ID' in
              ITU-T G.984.3 clause 5.5.5
              ITU-T G.987.3 clause 6.4.4
              ITU-T G.989.3, clause 6.1.5.8
              ITU-T G.9807.1 clause C.6.1.5.8";
    
          }
        }  // grouping ani-config-data
    
        grouping ani-state-data {
          description
            "State data from the Optical Network Unit (ONU) physical device.
    This data is fetched from the ONU physical device, when
    present, for instance via the Physical Layer Operations,
    Administrations and Maintenance (PLOAM) channel or using ONU
    Management and Control Interface (OMCI) on the Management
    G-PON Encapsulation Method (GEM) port.";
          leaf onu-id {
            type bbf-xpon-types:onu-id;
            description
              "This is the TC layer ONU-ID identifier which the Optical Line
    Termination (OLT) has assigned to the Optical Network Unit
    (ONU) during the ONU's activation using the Assign_ONU-ID
    Physical Layer Operations, Administrations and Maintenance
    (PLOAM) message.";
            reference
              "ITU-T G.984.3 clause 5.5.2
              ITU-T G.987.3 clause 6.4.2
              ITU-T G.9807.1 clause C.6.1.5.6
              ITU-T G.989.3 clause 6.1.5.6";
    
          }
    
          leaf onu-serial-number {
            if-feature bbf-xponani:ani-onu-serial-number-reporting;
            type bbf-xpon-types:onu-serial-number;
            mandatory true;
            description
              "The serial number of the Optical Network Unit (ONU).";
            reference
              "ITU-T G.984.3, clause 9.2.4.1
              ITU-T G.987.3, clause 11.3.3.2
              ITU-T G.9807.1, clauses C11.2.6.1, C11.2.6.2 and C11.3.4.1
              ITU-T G.989.3, clauses 11.2.6.1, 11.2.6.2 and 11.3.4.1.";
    
          }
    
          leaf channel-partition-id {
            type uint8;
            description
              "An index of the operator-specified channel subset in a
    NG-PON2 system. During operation, the Optical Network Units
    (ONUs) can be re-tuned between the channels within a channel
    partition, but not across the boundaries of the channel
    partition.";
          }
    
          leaf management-tcont-alloc-id {
            type uint32;
            description
              "The ITU-T Transmission Convergence (TC) Allocation Identifier
    (Alloc-ID) of the management Transmission Container (T-CONT)
    for the Optical Network Unit (ONU). It has the same numerical
    value as the ITU-T TC ONU-ID.";
            reference
              "Refer to 'Default Alloc-ID' in
              ITU-T G.987.3, clause 6.1.5.7
              ITU-T G.9807.1, clause C.6.1.5.7
              ITU-T G.987.3, clause 6.4.3
              ITU-T G.984.3, clause 5.5.3";
    
          }
    
          leaf management-gemport-id {
            type uint32;
            description
              "The ITU-T Transmission Convergence (TC) ID of the management
    G-PON Encapsulation Method (GEM) port for the Optical Network
    Unit (ONU). For NG-PON2, XGS-PON and XG-PON, it has the same
    numerical value as the ITU-T TC ONU-ID. For G-PON, its value
    is not necessarily numerically equal to the ONU-ID.";
            reference
              "Reefer to 'OMCC Port-ID' in
              ITU-T G.987.3, clause 6.1.5.8
              ITU-T G.9807.1, clause C.6.1.5.8
              ITU-T G.987.3, clause 6.4.4
              ITU-T G.984.3, clause 5.5.5";
    
          }
    
          leaf-list active-defects {
            if-feature bbf-xponani:ani-defects;
            type identityref {
              base bbf-xpon-def:items-detected-at-onu;
            }
            description
              "Defects detected by Optical Network Unit (ONU) for which
    Access Network Interface (ANI) is configured. All applicable
    identities should be reported.";
            reference
              "ITU-T G.984.3 (01/2014) 11.1.2
              ITU-T G.987.3 (01/2014) 14.2.2
              ITU-T G.989.3 (2015)/Amd.2 (11/2018) Table 14-3
              ITU-T G.9807.1 (2016)/Amd.1 (10/2017) Table C.14.3 ";
    
          }
        }  // grouping ani-state-data
    
        grouping onu-v-enet-config-data {
          description
            "Config data intended for the onu-v-enet interface.
    This data is brought to the Optical Network Unit (ONU) physical
    device, when present, for instance using ONU Management and
    Control Interface (OMCI) on the Management G-PON Encapsulation
    Method (GEM) port.";
          leaf ani {
            type if:interface-ref;
            must
              "derived-from-or-self(/if:interfaces/if:interface[if:name = current()]/if:type,'bbf-xponift:ani')";
            mandatory true;
            description
              "References the Access Network Interface (ANI) which is the
    lower-layer interface under the ONU-vENET.";
          }
        }  // grouping onu-v-enet-config-data
    
        grouping onu-v-vrefpoint-config-data {
          description
            "Config data intended for the onu-v-vrefpoint interface,
    (sometimes also called 'virtual User Network Interface (UNI)').
    This data is brought to the Optical Network Unit (ONU) physical
    device, when present, for instance using ONU Management and
    Control Interface (OMCI) on the Management G-PON Encapsulation
    Method (GEM) port.";
          leaf related-onu {
            type if:interface-ref;
            must
              "derived-from-or-self(/if:interfaces/if:interface[if:name = current()]/if:type,'bbf-xponift:ani')";
            mandatory true;
            description
              "References the Optical Network Unit (ONU) to which the
    virtual User Network Interface (UNI) relates.";
          }
        }  // grouping onu-v-vrefpoint-config-data
    
        // objects
        augment /if:interfaces/if:interface {
          when
            "derived-from-or-self(if:type, 'bbf-xponift:ani')";
          description
            "Augment interface configuration with xPON Access Newtork
    Interface (ANI) configuration.
    The ANI represents the Optical Network Unit (ONU) device.";
          container ani {
            description "ANI configuration.";
          }  // container ani
        }
    
        augment /if:interfaces/if:interface {
          when
            "derived-from-or-self(if:type, 'bbf-xponift:onu-v-enet')";
          description
            "Augment interface configuration with xPON Optical Network Unit
    (ONU) virtual ENET interface configuration.";
          container onu-v-enet {
            description
              "ONU virtual ENET configuration.";
          }  // container onu-v-enet
        }
    
        augment /if:interfaces/if:interface {
          when
            "derived-from-or-self(if:type,'bbf-xponift:onu-v-vrefpoint')";
          description
            "Augment interface configuration with xPON virtual V reference
    point interface per TR-167 (sometimes also called 'virtual User
    Network Interface (UNI)').";
          container onu-v-vrefpoint {
            description
              "Virtual User Network Interface (UNI) configuration.";
          }  // container onu-v-vrefpoint
        }
    
        augment /if:interfaces-state/if:interface {
          when
            "derived-from-or-self(if:type, 'bbf-xponift:ani')";
          description
            "Augment interface state data with xPON Access Network Interface
    (ANI) state data.
    The ANI represents the Optical Network Unit (ONU) device.";
          container ani {
            config false;
            description
              "State data for ANI interface.";
          }  // container ani
        }
    
        augment /if:interfaces/if:interface/bbf-xponani:ani {
          description
            "Configuration of an xPON Access Network Interface (ANI), i.e.
    an Optical Network Unit (ONU) device.";
          uses ani-config-data;
        }
    
        augment /if:interfaces-state/if:interface/bbf-xponani:ani {
          description
            "State data of an xPON Access Network Interface (ANI), i.e.
    an Optical Network Unit (ONU) device.";
          uses ani-state-data;
        }
    
        augment /if:interfaces/if:interface/bbf-xponani:onu-v-enet {
          description
            "Configuration of an xPON Optical Network Unit (ONU) virtual
    Ethernet (ENET) interface.";
          uses onu-v-enet-config-data;
        }
    
        augment /if:interfaces/if:interface/bbf-xponani:onu-v-vrefpoint {
          description
            "Configuration of an xPON Optical Network Unit (ONU) virtual V
    reference point interface per TR-167 (sometimes also called
    'virtual User Network Interface (UNI)').";
          reference
            "BBF TR-167";
    
          uses onu-v-vrefpoint-config-data;
        }
      }  // module bbf-xponani
    