iecieee60802-tt-mapping

This module provides information on characteristics of traffic classes configured in a network to allow applications to map app...

  • Version: 2024-12-13

    iecieee60802-tt-mapping@2024-12-13


    
      module iecieee60802-tt-mapping {
    
        yang-version 1.1;
    
        namespace
          "urn:ieee:std:60802:yang:iecieee60802-tt-mapping";
    
        prefix tt-mapping;
    
        import ieee802-dot1q-types {
          prefix dot1q-types;
        }
    
        organization
          "IEEE 802.1 Working Group and IEC subcommittee 65C:
         Industrial networks, of IEC technical committee 65:
         Industrial-process measurement, control and automation";
    
        contact
          "WG-URL: http://ieee802.org/1/
        WG-EMail: stds-802-1-l@ieee.org
        
        Contact: IEEE 802.1 Working Group Chair
        Postal: C/O IEEE 802.1 Working Group
               IEEE Standards Association
               445 Hoes Lane
               Piscataway, NJ 08854
               USA
        
        E-mail: stds-802-1-chairs@ieee.org";
    
        description
          "This module provides information on characteristics of traffic classes
         configured in a network to allow applications to map application traffic
         classes to them.
        
        Copyright (C) IEC/IEEE (2025).
        
        This version of this YANG module is part of IEC/IEEE 60802;
        see the standard itself for full legal notices.";
    
        revision "2024-12-13" {
          description
            "Published as part of IEC/IEEE 60802-2025.
    
          The following reference statement identifies each referenced
          IEEE Standard as updated by applicable amendments.";
          reference
            "IEC/IEEE 60802 TSN profile for industrial automation:
            IEC/IEEE 60802-2025.
            IEEE Std 802.1Q Bridges and Bridged Networks:
            IEEE Std 802.1Q-2022, IEEE Std 802.1Qcz-2023,
            IEEE Std 802.1Qcw-2023, IEEE Std 802.1Qdj-2024,
            IEEE Std 802.1Qdx-2024, IEEE Std 802.1Qdy-2025.";
    
        }
    
    
        container tt-mapping {
          description
            "Top-level container for the traffic class module.";
          list network {
            key "network-name";
            description
              "A list of networks, each containing one or more sets of traffic class
             characteristics.";
            leaf network-name {
              type string;
              description
                "The network-name uniquely identifies a network.";
            }
    
            list traffic-type {
              key "traffic-type-name";
              description
                "A list of traffic types in the network, each with its associated 
              traffic type characteristics.";
              leaf traffic-type-name {
                type string;
                description
                  "The traffic-type-name uniquely identifies the traffic type.";
              }
    
              leaf cyclic {
                type boolean;
                description
                  "Indicates if cyclic transmission is mandatory (TRUE) or optional (FALSE)
                 for this traffic type.";
                reference
                  "4.7.2 of IEC/IEEE 60802-2025";
    
              }
    
              leaf data-delivery-req {
                type enumeration {
                  enum "frame-latency" {
                    value 0;
                    description
                      "Data delivery of a frame for a given Talker-Listener pair 
                     occurs within a bounded timespan.";
                  }
                  enum "flow-latency" {
                    value 1;
                    description
                      "Data delivery up to a certain number of frames or data size
                     (including bursts of frames) occurring over a defined
                     period.";
                  }
                  enum "deadline" {
                    value 2;
                    description
                      "Data delivery of a frame to a given Listener occurs at or
                     before a specific point in time.";
                  }
                  enum "no" {
                    value 3;
                    description
                      "No special data delivery requirements.";
                  }
                }
                description
                  "The data-delivery-req provides information on the data 
               delivery requirements for this traffic type.";
                reference
                  "4.7.2 of IEC/IEEE 60802-2025";
    
              }
    
              leaf time-triggered {
                type boolean;
                description
                  "Indicates if it is required (TRUE) or optional (FALSE) that
                 transmission occurs at a specific point in time based upon
                 the Working Clock.";
                reference
                  "4.7.2 of IEC/IEEE 60802-2025";
    
              }
    
              leaf stream-based {
                type boolean;
                default 'true';
                description
                  "Indicates if traffic of this traffic type requires
                 registering a stream, i.e., allocating dedicated 
                 resources, for the  traffic, before a given Talker
                 can start transmitting data (TRUE), or if registering
                 a stream is not required (FALSE).";
                reference
                  "4.7.2 of IEC/IEEE 60802-2025";
    
              }
    
              leaf vlan-id {
                type dot1q-types:vlanid;
                description
                  "The VID this traffic type is mapped to.";
              }
    
              list redundancy {
                key "vlan-id-redundant";
                description
                  "A list of VIDs this traffic type is mapped to for redundant
               transmission. There is one entry in the list per redundant
               transmission ";
                leaf vlan-id-redundant {
                  type dot1q-types:vlanid;
                  description
                    "The VID this traffic type is mapped for a redundant transmission.";
                }
              }  // list redundancy
    
              leaf priority-value {
                type dot1q-types:priority-type;
                description
                  "The PCP this traffic type is mapped to.";
              }
            }  // list traffic-type
          }  // list network
        }  // container tt-mapping
      }  // module iecieee60802-tt-mapping
    