ieee802-dot1q-pb

This YANG module describes the bridge configuration model for Provider Bridges. Copyright (C) IEEE (2022). This version of thi...

  • Version: 2022-01-19

    ieee802-dot1q-pb@2022-01-19


    
      module ieee802-dot1q-pb {
    
        yang-version 1;
    
        namespace
          'urn:ieee:std:802.1Q:yang:ieee802-dot1q-pb';
    
        prefix dot1q-pb;
    
        import ieee802-dot1q-bridge {
          prefix dot1q;
        }
        import ieee802-dot1q-types {
          prefix dot1qtypes;
        }
        import ietf-interfaces {
          prefix if;
        }
    
        organization "IEEE 802.1 Working Group";
    
        contact
          "WG-URL: http://ieee802.org/1/
        WG-EMail: stds-802-1-l@ieee.org
        
        Contact: IEEE 802.1 Working Group Chair
        Postal: C/O IEEE 802.1 Working Group
               IEEE Standards Association
               445 Hoes Lane
               Piscataway, NJ 08854
               USA
        
        E-mail: stds-802-1-chairs@ieee.org";
    
        description
          "This YANG module describes the bridge configuration model for
        Provider Bridges.
        
        Copyright (C) IEEE (2022).
        
        This version of this YANG module is part of IEEE Std 802.1Q; see the
        standard itself for full legal notices.";
    
        revision "2022-01-19" {
          description
            "Published as part of IEEE Std 802.1Q-2022.";
          reference
            "IEEE Std 802.1Q-2022, Bridges and Bridged Networks.";
    
        }
    
        revision "2020-06-04" {
          description
            "Published as part of IEEE Std 802.1Qcx-2020. Second version.";
          reference
            "IEEE Std 802.1Qcx-2020, Bridges and Bridged Networks - YANG Data
            Model for Connectivity Fault Management.";
    
        }
    
        revision "2018-03-07" {
          description
            "Published as part of IEEE Std 802.1Q-2018. Initial version.";
          reference
            "IEEE Std 802.1Q-2018, Bridges and Bridged Networks.";
    
        }
    
    
        augment /if:interfaces/if:interface/dot1q:bridge-port {
          description
            "Augment the interface model with 802.1Q Bridge Port configuration
          specific nodes.";
          leaf svid {
            type dot1qtypes:vlanid;
            description
              "Service VLAN identifier.";
            reference
              "12.13.2.1 of IEEE Std 802.1Q-2022";
    
          }
    
          list cvid-registration {
            when
              "../dot1q:component-name = 'dot1q:c-vlan-component' and "
                + "../dot1q:port-type = 'dot1q:customer-edge-port'" {
              description
                "Applies when the component associated with this interface is
              a C-VLAN component and the port-type is a customer edge port.";
            }
            key "cvid";
            description
              "The C-VID Registration Table, provides a mapping between a
            C-VID and the service instance represented by an S-VID selected
            for that C-VLAN. This table provides the equivalent
            functionality of
               1) Configuring the PVID of the internal CNP on the S-VLAN
                  component
               2) Adding the corresponding PEP on the C-VLAN component to
                  the member set of the C-VLAN
               3) Adding the PEP and/or CEP to the untagged set of the
                  C-VLAN (if it is desired that frames forwarded to that
                  port are transmitted untagged for this C-VLAN).";
            leaf cvid {
              type dot1qtypes:vlanid;
              description
                "Customer VLAN identifiers associated with this bridge port.";
              reference
                "12.13.2.1 of IEEE Std 802.1Q-2022";
    
            }
    
            leaf svid {
              type dot1qtypes:vlanid;
              description
                "Service VLAN identifier.";
              reference
                "12.13.2.1 of IEEE Std 802.1Q-2022";
    
            }
    
            leaf untagged-pep {
              type boolean;
              default "true";
              description
                "A boolean indicating frames for this C-VLAN should be
              forwarded untagged through the Provider Edge Port.";
              reference
                "12.13.2.1 of IEEE Std 802.1Q-2022";
    
            }
    
            leaf untagged-cep {
              type boolean;
              default "true";
              description
                "A boolean indicating frames for this C-VLAN should be
              forwarded untagged through the Customer Edge Port.";
              reference
                "12.13.2.1 of IEEE Std 802.1Q-2022";
    
            }
          }  // list cvid-registration
    
          list service-priority-regeneration {
            when
              "../dot1q:component-name = 'dot1q:c-vlan-component' and "
                + "../dot1q:port-type = 'dot1q:customer-edge-port'" {
              description
                "Applies when the component associated with this interface is
              a C-VLAN component and the port-type is a customer edge port.";
            }
            key "svid";
            description
              "The Service Priority Regeneration Table, which provides the
            Priority Regeneration Table (12.6.2) for each internal CNP
            connected to the C-VLAN component associated with the CEP.";
            leaf svid {
              type dot1qtypes:vlanid;
              description
                "Service VLAN identifier.";
              reference
                "12.13.2.6 of IEEE Std 802.1Q-2022";
    
            }
    
            container priority-regeneration {
              description
                "Contains Service Priority Regeneration table nodal
              information.";
              reference
                "12.13.2.6 of IEEE Std 802.1Q-2022";
    
              uses dot1qtypes:priority-regeneration-table-grouping;
            }  // container priority-regeneration
          }  // list service-priority-regeneration
    
          list rcap-internal-interface {
            when
              "../dot1q:component-name = 'dot1q:s-vlan-component' and "
                + "../dot1q:port-type = 'dot1q:remote-customer-access-port'" {
              description
                "Applies when the component associated with this interface is
              a C-VLAN component and the port-type is a customer edge port.";
            }
            key "external-svid";
            description
              "Designating an external port as an RCAP automatically creates a
            Port-mapping S-VLAN component associated with that port. This
            Port-mapping S-VLAN component includes one internal PNP.";
            leaf external-svid {
              type dot1qtypes:vlanid;
              description
                "External Service VLAN identifier.";
              reference
                "12.13.3.2 of IEEE Std 802.1Q-2022";
    
            }
    
            leaf internal-port-number {
              type dot1qtypes:port-number-type;
              description
                "The number of the RCAP.";
              reference
                "12.13.3.2 of IEEE Std 802.1Q-2022";
    
            }
    
            leaf internal-svid {
              type dot1qtypes:vlanid;
              description
                "Internal Service VLAN Identifier (not applicable for a
              C-tagged RCSI).";
              reference
                "12.13.3.2 of IEEE Std 802.1Q-2022";
    
            }
    
            leaf internal-interface-type {
              type enumeration {
                enum "port-based-rcsi" {
                  value 0;
                  description "Port-based RCSI";
                }
                enum "c-tagged-rcsi" {
                  value 1;
                  description "C-tagged RCSI";
                }
                enum "pnp" {
                  value 2;
                  description
                    "Provider Network Port";
                }
                enum "discard" {
                  value 3;
                  description
                    "Discard (external S-VID is not associated with an
                  internal port).";
                }
              }
              description
                "A value indicating the type of internal interface associated
              with the external S-VID.";
              reference
                "12.13.3.2 of IEEE Std 802.1Q-2022";
    
            }
          }  // list rcap-internal-interface
        }
      }  // module ieee802-dot1q-pb
    