bbf-fast-upstream-power-back-off-profile-body

This submodule contains a collection of YANG definitions for managing upstream power back off profiles. Copyright (c) 2016-2022...

  • Version: 2022-05-23

    bbf-fast-upstream-power-back-off-profile-body@2022-05-23


    
      submodule bbf-fast-upstream-power-back-off-profile-body {
    
        yang-version 1.1;
    
        belongs-to bbf-fast {
            prefix bbf-fast;
        }
    
        organization
          "Broadband Forum <https://www.broadband-forum.org>
         Common YANG Work Area";
    
        contact
          "Comments or questions about this Broadband Forum YANG module
         should be directed to <mailto:help@broadband-forum.org>.
    
         Editor:      Ken Kerpez, ASSIA, Inc.
    
         Editor:      Joey Boyd, Adtran
    
         PS Leader:   Joey Boyd, Adtran
    
         WA Director: Sven Ooghe, Nokia
    
         WA Director: Joey Boyd, Adtran";
    
        description
          "This submodule contains a collection of YANG definitions for
         managing upstream power back off profiles.
    
         Copyright (c) 2016-2022 Broadband Forum
    
         Redistribution and use in source and binary forms, with or
         without modification, are permitted provided that the following
         conditions are met:
    
         1. Redistributions of source code must retain the above copyright
            notice, this list of conditions and the following disclaimer.
    
         2. Redistributions in binary form must reproduce the above
            copyright notice, this list of conditions and the following
            disclaimer in the documentation and/or other materials
            provided with the distribution.
    
         3. Neither the name of the copyright holder nor the names of its
            contributors may be used to endorse or promote products
            derived from this software without specific prior written
            permission.
    
         THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
         CONTRIBUTORS \"AS IS\" AND ANY EXPRESS OR IMPLIED WARRANTIES,
         INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
         MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
         DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
         CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
         SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
         NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
         LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
         CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
         STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
         ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
         ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
    
         The above license is used as a license under copyright only.
         Please reference the Forum IPR Policy for patent licensing terms
         <https://www.broadband-forum.org/ipr-policy>.
    
         Any moral rights which are necessary to exercise under the above
         license grant are also deemed granted under this license.
    
         This version of this YANG module is part of TR-355a4; see
         the TR itself for full legal notices.";
    
        revision "2022-05-23" {
          description
            "Amendment 4.
           * Approval Date:    2022-05-23
           * Publication Date: 2022-05-23.";
          reference
            "TR-355a4: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-4.pdf>";
    
        }
    
        revision "2020-10-13" {
          description
            "Amendment 3.
           * Approval Date:    2020-10-13
           * Publication Date: 2020-10-13.";
          reference
            "TR-355a3: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-3.pdf>";
    
        }
    
        revision "2020-01-17" {
          description
            "Amendment 2 Corrigendum 2.
           * Approval Date:    2020-01-17
           * Publication Date: 2020-01-17.";
          reference
            "TR-355a2c2: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-2.pdf>";
    
        }
    
        revision "2019-10-21" {
          description
            "Amendment 2 Corrigendum 1.
           * Approval Date:    2019-10-21
           * Publication Date: 2019-10-21.";
          reference
            "TR-355a2c1: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-2.pdf>";
    
        }
    
        revision "2019-06-11" {
          description
            "Amendment 2.
           * Approval Date:    2019-06-11
           * Publication Date: 2019-06-11.";
          reference
            "TR-355a2: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Amendment-2.pdf>";
    
        }
    
        revision "2018-10-01" {
          description
            "Amendment 1.
           * Approval Date:    2018-10-01
           * Publication Date: 2018-10-01.";
          reference
            "TR-355a1: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Amendment-1.pdf>";
    
        }
    
        revision "2016-07-18" {
          description
            "Initial revision.
           * Approval Date:    see revision date above.
           * Publication Date: 2016-08-05.";
          reference
            "TR-355: YANG Modules for FTTdp Management
            	<https://www.broadband-forum.org/technical/download/
            		 TR-355.pdf>";
    
        }
    
    
        grouping upstream-power-back-off-parameters {
          description
            "Power-back-off-specific configuration parameters.";
          reference
            "ITU-T G.997.2 clause 7.1.2";
    
          leaf upbopsd-a {
            type uint16 {
              range "0..4095";
            }
            units "0.01 dBm per Hz";
            default "0";
            description
              "Defines the parameter a for the Upstream power back-off
             (UPBO) reference Power Spectral Density (PSD) used to
             compute the upstream power back-off for the upstream
             frequency band.";
            reference
              "ITU-T G.997.2 clause 7.1.2.9 (UPBOPSDA);
              ITU-T G.9701 clause 7.3.1.4";
    
          }
    
          leaf upbopsd-b {
            type uint16 {
              range "0..4095";
            }
            units "0.01 dBm per Hz";
            default "0";
            description
              "Defines the parameter b for the Upstream power back-off
             (UPBO) reference Power Spectral Density (PSD) used to
             compute the upstream power back-off for the upstream
             frequency band.";
            reference
              "ITU-T G.997.2 clause 7.1.2.10 (UPBOPSDB);
              ITU-T G.9701 clause 7.3.1.4";
    
          }
    
          leaf upbo-upstream-electrical-length {
            type uint16 {
              range "0..1280";
            }
            units "0.1 dB";
            default "0";
            description
              "Defines the electrical length kl0 (expressed in dB at
             1 MHz).";
            reference
              "ITU-T G.997.2 clause 7.1.2.11 (UPBOKL);
              ITU-T G.9701 clause 7.3.1.4.2.1";
    
          }
    
          leaf upbo-force-electrical-length {
            type boolean;
            default "false";
            description
              "Defines whether or not the FAST Transceiver Unit - Remote
             side (FTU-R) is forced to use the electrical length kl0 =
             UPBOKL to compute the UPBOMASK. If not forced, the FAST
             Transceiver Units (FTU) determine the electrical length
             kl0.";
            reference
              "ITU-T G.997.2 clause 7.1.2.12 (UPBOKLF);
              ITU-T G.9701 clause 7.3.1.4.2.1";
    
          }
    
          leaf upbo-reference-electrical-length {
            type uint16 {
              range "0 | 18..255";
            }
            units "0.1 dB";
            default "0";
            description
              "Defines the Upstream power back-off (UPBO) reference
             electrical length kl0_REF used to compute the upstream power
             back-off for the Equalized Far-End Crosstalk (FEXT) Upstream
             power back-off (UPBO) method. If kl0_REF = 0 (special value)
             then the Equal Power Spectral Density (PSD) Upstream power
             back-off (UPBO) method is used.";
            reference
              "ITU-T G.997.2 clause 7.1.2.13 (UPBOKLREF);
              ITU-T G.9701 clause 7.3.1.4.2.2";
    
          }
        }  // grouping upstream-power-back-off-parameters
    
        grouping upstream-power-back-off-profile {
          description
            "Defines the parameters contained in an upstream power back-off
           profile.";
          uses upstream-power-back-off-parameters;
        }  // grouping upstream-power-back-off-profile
      }  // submodule bbf-fast-upstream-power-back-off-profile-body
    