bbf-gbond

This module contains a collection of YANG definitions for supporting the Broadband Forum requirements on bonding of physical int...

  • Version: 2022-05-23

    bbf-gbond@2022-05-23


    
      module bbf-gbond {
    
        yang-version 1.1;
    
        namespace "urn:bbf:yang:bbf-gbond";
    
        prefix bbf-gbond;
    
        import iana-if-type {
          prefix ianaift;
        }
        import ietf-interfaces {
          prefix if;
        }
        import bbf-fastdsl {
          prefix bbf-fastdsl;
        }
        import bbf-yang-types {
          prefix bbf-yang;
        }
    
        organization
          "Broadband Forum <https://www.broadband-forum.org>
         Common YANG Work Area";
    
        contact
          "Comments or questions about this Broadband Forum YANG module
         should be directed to <mailto:help@broadband-forum.org>.
    
         Editor:      Ken Kerpez, ASSIA, Inc.
    
         Editor:      Joey Boyd, Adtran
    
         PS Leader:   Joey Boyd, Adtran
    
         WA Director: Sven Ooghe, Nokia
    
         WA Director: Joey Boyd, Adtran";
    
        description
          "This module contains a collection of YANG definitions for
         supporting the Broadband Forum requirements on bonding of
         physical interfaces as defined in ITU-T G.998.1, ITU-T G.998.2,
         ITU-T G.998.3 and BBF TR-159. As such, this module is specfic to
         access network equipment (e.g., BBF-specified Access Nodes and
         FTTdp DPUs).
    
         Copyright (c) 2016-2022 Broadband Forum
    
         Redistribution and use in source and binary forms, with or
         without modification, are permitted provided that the following
         conditions are met:
    
         1. Redistributions of source code must retain the above copyright
            notice, this list of conditions and the following disclaimer.
    
         2. Redistributions in binary form must reproduce the above
            copyright notice, this list of conditions and the following
            disclaimer in the documentation and/or other materials
            provided with the distribution.
    
         3. Neither the name of the copyright holder nor the names of its
            contributors may be used to endorse or promote products
            derived from this software without specific prior written
            permission.
    
         THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
         CONTRIBUTORS \"AS IS\" AND ANY EXPRESS OR IMPLIED WARRANTIES,
         INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
         MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
         DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
         CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
         SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
         NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
         LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
         CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
         STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
         ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
         ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
    
         The above license is used as a license under copyright only.
         Please reference the Forum IPR Policy for patent licensing terms
         <https://www.broadband-forum.org/ipr-policy>.
    
         Any moral rights which are necessary to exercise under the above
         license grant are also deemed granted under this license.
    
         This version of this YANG module is part of TR-355a4; see
         the TR itself for full legal notices.";
    
        revision "2022-05-23" {
          description
            "Amendment 4.
           * Approval Date:    2022-05-23
           * Publication Date: 2022-05-23.";
          reference
            "TR-355a4: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-4.pdf>";
    
        }
    
        revision "2020-10-13" {
          description
            "Amendment 3.
           * Approval Date:    2020-10-13
           * Publication Date: 2020-10-13.";
          reference
            "TR-355a3: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-3.pdf>";
    
        }
    
    
        feature bonding-primary-interface {
          description
            "Indicates support for assigning one of the interfaces of the
           bonding group as the primary interface.";
        }
    
        feature bonding-group-statistics {
          description
            "Indicates support for statistics associated with a bonding
           group.";
        }
    
        feature bonding-group-performance {
          description
            "Indicates support for performance associated with a bonding
           group.";
        }
    
        feature bonding-group-performance-15min {
          if-feature bonding-group-performance;
          description
            "Indicates support for 15 minute interval performance statistics
           associated with a bonding group.";
        }
    
        feature bonding-group-performance-24hr {
          if-feature bonding-group-performance;
          description
            "Indicates support for 24 hour interval performance statistics
           associated with a bonding group.";
        }
    
        identity control-protocol {
          description
            "Bonding control protocol for a G.998.2 based bonding group.";
        }
    
        identity ghs {
          base control-protocol;
          description "G.hs based discovery.";
        }
    
        identity bacp {
          base control-protocol;
          description
            "Bonding Aggregation Control Protocol.";
        }
    
        typedef undefined {
          type enumeration {
            enum "undefined" {
              value 0;
              description
                "Indicates data is not yet configured or available for
               reporting.";
            }
          }
          description
            "Provides an enumeration for reporting data is undefined.";
        }
    
        typedef boolean-or-undefined {
          type union {
            type undefined;
            type boolean;
          }
          description
            "Boolean type which also provides a means of reporting that the
           value is undefined rather than true or false.";
        }
    
        typedef bonding-group-profile-ref {
          type leafref {
            path "/bbf-gbond:gbond/bbf-gbond:profiles/bbf-gbond:bonding-group/bbf-gbond:profile/bbf-gbond:name";
          }
          description
            "Used to reference a bonding group profile.";
        }
    
        typedef bonding-group-threshold-profile-ref {
          type leafref {
            path "/bbf-gbond:gbond/bbf-gbond:thresholds/bbf-gbond:bonding-group/bbf-gbond:threshold-profile/bbf-gbond:name";
          }
          description
            "Used to reference a line threshold profile.";
        }
    
        typedef bonding-group-threshold-template-ref {
          type leafref {
            path "/bbf-gbond:gbond/bbf-gbond:thresholds/bbf-gbond:bonding-group/bbf-gbond:threshold-template/bbf-gbond:name";
          }
          description
            "Used to reference a bonding group threshold template.";
        }
    
        container gbond {
          description "G.bond configuration.";
          container profiles {
            description "Profile configuration.";
            container bonding-group {
              description
                "Profile configuration specific to a bonding group.";
              list profile {
                key "name";
                description
                  "Profile defining the bonding group configuration.";
                leaf name {
                  type bbf-yang:string-ascii64;
                  description
                    "Uniquely identifies the configuration profile.";
                }
    
                leaf target-upstream-data-rate {
                  type bbf-yang:data-rate32;
                  default "4294967295";
                  description
                    "A desired maximum operating data rate of the Generic
                   Bonded Sub-layer (GBS) in the upstream direction, in
                   kilobits per second.";
                  reference
                    "TR-159 section 5.5.1.17, aGroupTargetUpRate.";
    
                }
    
                leaf target-downstream-data-rate {
                  type bbf-yang:data-rate32;
                  default "4294967295";
                  description
                    "A desired maximum operating data rate of the Generic
                   Bonded Sub-layer (GBS) in the downstream direction, in
                   kilobits per second.";
                  reference
                    "TR-159 section 5.5.1.18, aGroupTargetDownRate.";
    
                }
    
                leaf low-upstream-data-rate-threshold {
                  type bbf-yang:data-rate32;
                  default "0";
                  description
                    "A desired G.998.x port low upstream rate crossing alarm
                   threshold, in kilobits per second.
    
                   When the current value of upstream-data-rate for this
                   port reaches/drops below or exceeds this threshold, a
                   notification MAY be generated.
    
                   A value of 0 effectively disables any notification.";
                  reference
                    "TR-159 section 5.5.1.21, aGroupThreshLowUpRate.";
    
                }
    
                leaf low-downstream-data-rate-threshold {
                  type bbf-yang:data-rate32;
                  default "0";
                  description
                    "A desired G.998.x port low downstream rate crossing
                   alarm threshold, in kilobits per second.
    
                   When the current value of downstream-data-rate for this
                   port reaches/drops below or exceeds this threshold, a
                   notification MAY be generated.
    
                   A value of 0 effectively disables any notification.";
                  reference
                    "TR-159 section 5.5.1.22, aGroupThreshLowDownRate.";
    
                }
              }  // list profile
            }  // container bonding-group
          }  // container profiles
    
          container thresholds {
            description
              "Threshold configuration.";
            container bonding-group {
              if-feature bonding-group-performance;
              description
                "Threshold configuration specific to a bonding group.";
              list threshold-profile {
                key "name";
                description
                  "Profile defining the threshold for bonding group specific
                 performance parameters.";
                leaf name {
                  type bbf-yang:string-ascii64;
                  description
                    "Uniquely identifies the bonding group threshold
                   profile.";
                }
    
                leaf errored-seconds-threshold {
                  type uint32;
                  units "seconds";
                  default "0";
                  description
                    "Threshold for the count of errored seconds (ES). A
                   special value (0) indicates the threshold is
                   disabled.";
                }
    
                leaf severely-errored-seconds-threshold {
                  type uint32;
                  units "seconds";
                  default "0";
                  description
                    "Threshold for the count of severely errored seconds
                   (SES). A special value (0) indicates the threshold is
                   disabled.";
                }
    
                leaf unavailable-seconds-threshold {
                  type uint32;
                  units "seconds";
                  default "0";
                  description
                    "Threshold for the count of unavailable seconds (UAS). A
                   special value (0) indicates the threshold is
                   disabled.";
                }
              }  // list threshold-profile
    
              list threshold-template {
                key "name";
                description
                  "A template defining the threshold profiles to apply to
                 performance parameters of a G.bond interface.";
                leaf name {
                  type bbf-yang:string-ascii64;
                  description
                    "Uniquely identifies the line configuration vector.";
                }
    
                leaf gbs-c-15min-threshold-profile {
                  if-feature bonding-group-performance-15min;
                  type bonding-group-threshold-profile-ref;
                  mandatory true;
                  description
                    "Reference to a line threshold profile for Generic
                   Bonded Sub-layer, CO side (GBS-C) thresholds related to
                   15 minute performance counters.";
                }
    
                leaf gbs-c-24hr-threshold-profile {
                  if-feature bonding-group-performance-24hr;
                  type bonding-group-threshold-profile-ref;
                  mandatory true;
                  description
                    "Reference to a line threshold profile for Generic
                   Bonded Sub-layer, CO side (GBS-C) thresholds related to
                   24 hour performance counters.";
                }
              }  // list threshold-template
            }  // container bonding-group
          }  // container thresholds
        }  // container gbond
    
        augment /if:interfaces/if:interface {
          when
            "derived-from-or-self(if:type,'ianaift:g9981') or "
              + "derived-from-or-self(if:type,'ianaift:g9982') or "
              + "derived-from-or-self(if:type,'ianaift:g9983')" {
            description
              "Only applicable if the interface type is G.998.1, G.998.2,
             G.998.3, or derived from one of those types.";
          }
          description
            "Augment the basic interface configuration with parameters
           associated with a G.bond bonding group.";
          container bonding-group {
            presence
              "The presence of this container indicates that this interface
             is a bonding group representing a Generic Bonded Sub-layer
             interface per TR-159.";
            description
              "Configuration parameters associated with a bonding group.";
            leaf profile {
              type bonding-group-profile-ref;
              mandatory true;
              description
                "Assigns a profile to a bonding group.";
            }
    
            leaf threshold-template {
              if-feature bonding-group-performance;
              type bonding-group-threshold-template-ref;
              description
                "Assigns a threshold template to a bonding group. If no
               threshold template is assigned, threshold crossing alert
               (TCA) reporting for all thresholds is disabled.";
            }
    
            leaf bonded-interface-mode {
              type bbf-fastdsl:fastdsl-mode-ref;
              mandatory true;
              description
                "The intended FastDSL mode of operation for all lines
               associated with the bonded group.";
            }
    
            leaf-list lower-layer-if {
              type if:interface-ref;
              must
                "/if:interfaces/if:interface[if:name=current()]
                  /if:type='ianaift:fastdsl' and
                  /if:interfaces/if:interface[if:name=current()]
                  /bbf-fastdsl:line/bbf-fastdsl:configured-mode=
                  ../bonded-interface-mode" {
                error-message
                  "Either the type of interface is not derived from or "
                    + "equal to 'ianaift:fastdsl' or the interface is not of "
                    + "the same configured mode as the bonded interface mode "
                    + "for this group.";
                description
                  "Each lower layer interface must be either a 'fastdsl'
                 interface or an interface type derived from 'fastdsl'
                 and must also be of the same configured mode as the
                 overall bonded interface mode for the bonding group.";
              }
              min-elements 1;
              description
                "A reference to an interface representing a bonded channel
               entity.";
            }
    
            leaf primary-interface {
              if-feature bonding-primary-interface;
              type if:interface-ref;
              must
                'current() = current()/../lower-layer-if' {
                error-message
                  "The primary interface must be an interface configured as"
                    + " a lower layer interface of this bonding group.";
                description
                  "The primary interface must be an interface configured as
                 a lower layer interface of this bonding group.";
              }
              mandatory true;
              description
                "Mulitple protocols, such as ANCP and DHCPv4, define PDUs
               that contains an 'Access Loop Circuit Id' (the terminology
               is protocol dependent) which is to be generated by the
               Access Node and which identifies the position in the
               hardware where the line is physically connected to. When
               such identification is to be generated for a bonding group,
               then the issue is that this bonding group is composed of
               multiple physical lines. In that situation the leaf
               'primary-interface' identifies from which FastDSL line /
               interface / port the access loop identification will be
               generated.";
            }
    
            notification low-upstream-data-rate-crossing {
              description
                "This notification indicates that the G.998.x port upstream
               data rate has reached/dropped below or exceeded the low
               upstream rate threshold, specified by
               'low-upstream-data-rate-threshold'.
    
               This notification MAY be sent for the Generic Bonded
               Sub-layer, CO side (GBS-C) ports while the port is up, on
               the crossing event in both directions: from normal (rate is
               above the threshold) to low (rate equals the threshold or
               below it) and from low to normal. This notification is not
               applicable to the Generic Bonded Sub-layer, RT side (GBS-R)
               ports.
    
               Generation of this notification is controlled by the
               setting the 'low-upstream-data-rate-threshold' to 0.";
              reference
                "TR-159 section 5.5.1.24, nGroupLowUpRateCrossing";
    
              leaf event {
                type enumeration {
                  enum "normal-to-low" {
                    value 0;
                    description
                      "G.998.x port upstream data rate has reached/dropped
                     below the low upstream rate threshold.";
                  }
                  enum "low-to-normal" {
                    value 1;
                    description
                      "G.998.x port upstream data rate has exceeded the
                     low upstream rate threshold.";
                  }
                }
                description
                  "The type of threshold crossing event that triggered the
                 notification.";
              }
            }  // notification low-upstream-data-rate-crossing
    
            notification low-downstream-data-rate-crossing {
              description
                "This notification indicates that the G.998.x port
               downstream data rate has reached/dropped below or exceeded
               the low downstream rate threshold, specified by
               'low-downstream-data-rate-threshold'.
    
               This notification MAY be sent for the Generic Bonded
               Sub-layer, CO side (GBS-C) ports while the port is up, on
               the crossing event in both directions: from normal (rate is
               above the threshold) to low (rate equals the threshold or
               below it) and from low to normal. This notification is not
               applicable to the Generic Bonded Sub-layer, RT side (GBS-R)
               ports.
    
               Generation of this notification is controlled by the
               setting the 'low-downstream-data-rate-threshold' to 0.";
              reference
                "TR-159 section 5.5.1.25, nGroupLowDownRateCrossing";
    
              leaf event {
                type enumeration {
                  enum "normal-to-low" {
                    value 0;
                    description
                      "G.998.x port downstream data rate has reached/dropped
                     below the low downstream rate threshold.";
                  }
                  enum "low-to-normal" {
                    value 1;
                    description
                      "G.998.x port downstream data rate has exceeded the
                     low downstream rate threshold.";
                  }
                }
                description
                  "The type of threshold crossing event that triggered the
                 notification.";
              }
            }  // notification low-downstream-data-rate-crossing
    
            notification link-up {
              description
                "This notification indicates that the G.998.x interface has
               transitioned to an 'up' status, as specified by
               'oper-status'.";
              reference
                "TR-159 section 5.5.1.27, nGroupLinkUp";
    
            }  // notification link-up
    
            notification link-down {
              description
                "This notification indicates that the G.998.x interface has
               transitioned to an 'down' status, as specified by
               'oper-status'.";
              reference
                "TR-159 section 5.5.1.28, nGroupLinkDown";
    
            }  // notification link-down
          }  // container bonding-group
        }
      }  // module bbf-gbond
    

© 2023 YumaWorks, Inc. All rights reserved.