bbf-melt-pmd-profile-body

This submodule contains a collection of YANG definitions for managing Physical Medium Dependent (PMD) profiles. Copyright (c) 2...

  • Version: 2022-05-23

    bbf-melt-pmd-profile-body@2022-05-23


    
      submodule bbf-melt-pmd-profile-body {
    
        yang-version 1.1;
    
        belongs-to bbf-melt {
            prefix bbf-melt;
        }
    
        organization
          "Broadband Forum <https://www.broadband-forum.org>
         Common YANG Work Area";
    
        contact
          "Comments or questions about this Broadband Forum YANG module
         should be directed to <mailto:help@broadband-forum.org>.
    
         Editor:      Ken Kerpez, ASSIA, Inc.
    
         Editor:      Joey Boyd, Adtran
    
         PS Leader:   Joey Boyd, Adtran
    
         WA Director: Sven Ooghe, Nokia
    
         WA Director: Joey Boyd, Adtran";
    
        description
          "This submodule contains a collection of YANG definitions for
         managing Physical Medium Dependent (PMD) profiles.
    
         Copyright (c) 2016-2022 Broadband Forum
    
         Redistribution and use in source and binary forms, with or
         without modification, are permitted provided that the following
         conditions are met:
    
         1. Redistributions of source code must retain the above copyright
            notice, this list of conditions and the following disclaimer.
    
         2. Redistributions in binary form must reproduce the above
            copyright notice, this list of conditions and the following
            disclaimer in the documentation and/or other materials
            provided with the distribution.
    
         3. Neither the name of the copyright holder nor the names of its
            contributors may be used to endorse or promote products
            derived from this software without specific prior written
            permission.
    
         THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
         CONTRIBUTORS \"AS IS\" AND ANY EXPRESS OR IMPLIED WARRANTIES,
         INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
         MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
         DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
         CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
         SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
         NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
         LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
         CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
         STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
         ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
         ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
    
         The above license is used as a license under copyright only.
         Please reference the Forum IPR Policy for patent licensing terms
         <https://www.broadband-forum.org/ipr-policy>.
    
         Any moral rights which are necessary to exercise under the above
         license grant are also deemed granted under this license.
    
         This version of this YANG module is part of TR-355a4; see
         the TR itself for full legal notices.";
    
        revision "2022-05-23" {
          description
            "Amendment 4.
           * Approval Date:    2022-05-23
           * Publication Date: 2022-05-23.";
          reference
            "TR-355a4: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-4.pdf>";
    
        }
    
        revision "2020-10-13" {
          description
            "Amendment 3.
           * Approval Date:    2020-10-13
           * Publication Date: 2020-10-13.";
          reference
            "TR-355a3: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-3.pdf>";
    
        }
    
        revision "2019-06-11" {
          description
            "Amendment 2.
           * Approval Date:    2019-06-11
           * Publication Date: 2019-06-11.";
          reference
            "TR-355a2: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Amendment-2.pdf>";
    
        }
    
        revision "2018-10-01" {
          description
            "Amendment 1.
           * Approval Date:    2018-10-01
           * Publication Date: 2018-10-01.";
          reference
            "TR-355a1: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Amendment-1.pdf>";
    
        }
    
        revision "2017-11-27" {
          description
            "Corrigendum 2 (fixes to the previous revision).
           * Approval Date:    see revision date above.
           * Publication Date: 2018-01-19.";
          reference
            "TR-355c2: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Corrigendum-2.pdf>";
    
        }
    
        revision "2016-07-18" {
          description
            "Initial revision.
           * Approval Date:    see revision date above.
           * Publication Date: 2016-08-05.";
          reference
            "TR-355: YANG Modules for FTTdp Management
            	<https://www.broadband-forum.org/technical/download/
            		 TR-355.pdf>";
    
        }
    
    
        identity measurement-class {
          description
            "Base identity for defining the various measurements.";
        }
    
        grouping pmd-profile {
          description
            "Defines the parameters contained in a Physical Medium Dependent
           (PMD) profile.";
          leaf peak-metallic-voltage-tr {
            type uint8 {
              range "0..150";
            }
            units "volts";
            description
              "This parameter defines the peak metallic voltage which must
             not be exceeded in any active measurement applying a
             metallic voltage between tip and ring in order not to
             conduct current in a non-linear termination located at the
             far-end during the measurement. The range of valid values is
             from 0 to 150 volts with a granularity of 1 volts. In the
             case of a test performed with a sinewave signal, it applies
             to the peak of the sinewave, not to its RMS value.";
            reference
              "ITU-T G.996.2 clause E.2.1.2 (MELT-PV)";
    
          }
    
          leaf pair-identification-tone-frequency {
            type uint16 {
              range "300..3400";
            }
            units "Hz";
            description
              "This parameter sets up frequency of the pair identification
             tone as defined in clause E.1.2.1. The range of frequencies
             is from 300 to 3400 Hz in granularity of 1 Hz.
             The supported set of frequencies is at the vendor's
             discretion.";
            reference
              "ITU-T G.996.2 clause E.2.1.4 (MELT-PIT-F)";
    
          }
    
          leaf pair-identification-tone-timeout {
            type uint16 {
              range "1..65535";
            }
            units "seconds";
            description
              "This parameter specifies the duration of the pair
             identification tone. After timeout the pair identification
             tone is deactivated automatically, if not deactivated
             manually before (abort).";
            reference
              "ITU-T G.996.2 clause E.2.1.5 (MELT-PIT-T)";
    
          }
    
          leaf maximum-far-end-signature-conductive-voltage {
            type uint16 {
              range "0..500";
            }
            units "0.1 volts";
            description
              "This parameter specifies the maximum conduction voltage
             level of an expected far-end signature. It defines the
             minimum metallic voltage required for all measurements with
             a high metallic voltage between tip and ring in order to
             conduct current in a far-end signature during the
             measurement. The range of valid values is from 0 to 50 volts
             with a granularity of 0.1 volts.";
            reference
              "ITU-T G.996.2 clause E.2.1.5 (MELT-MAXFE-SCV)";
    
          }
    
          leaf minimum-far-end-signature-conductive-voltage {
            type uint16 {
              range "0..500";
            }
            units "0.1 volts";
            description
              "This parameter specifies the minimum conduction voltage
             level of an expected far-end signature. It defines the
             maximum metallic voltage allowed for all measurements with a
             controlled metallic voltage between tip and ring in order
             not to conduct current in a far-end signature during the
             measurement. The range of valid values is from 0 to 50 volts
             with a granularity of 0.1 volts. In the case of a measurement
             performed with a sinewave signal, it applies to the peak of
             the sinewave, not to its RMS value.";
            reference
              "ITU-T G.996.2 clause E.2.1.6 (MELT-MINFE-SCV)";
    
          }
    
          leaf-list measurement-class {
            type identityref {
              base measurement-class;
            }
            ordered-by user;
            description
              "This parameter defines the list of measurements to be
             executed. It shall support a single measurement or a set of
             MELT measurements in a consecutive manner. The measurements
             of interest are selected via a flag register, or equivalent.
             If no elements exist, no measurements will be executed.";
            reference
              "ITU-T G.996.2 clause E.2.1.1 (MELT-MCLASS)";
    
          }
    
          leaf signal-frequency-for-active-ac-tests {
            type uint16 {
              range "10..1000";
            }
            units "Hz";
            description
              "This parameter controls the frequency used during the
             3-element capacitance test, if performed with a sinewave
             signal, and during the 3-element complex admittance test.
             This parameter shall be represented in linear format with
             values from 10 to 1000 Hz with a granularity of 1 Hz.
    
             The supported set of frequencies is at the vendor's
             discretion with an option to operate in automatic mode for
             which the testing routine will select the frequency on its
             own.";
            reference
              "ITU-T G.996.2 clause E.2.1.3 (MELT-AC-F)";
    
          }
        }  // grouping pmd-profile
      }  // submodule bbf-melt-pmd-profile-body
    

© 2023 YumaWorks, Inc. All rights reserved.