bbf-selt-pmd-control-body

This submodule contains a collection of YANG definitions for managing the Physical Medium Dependent (PMD) control object. Copyr...

  • Version: 2022-05-23

    bbf-selt-pmd-control-body@2022-05-23


    
      submodule bbf-selt-pmd-control-body {
    
        yang-version 1.1;
    
        belongs-to bbf-selt {
            prefix bbf-selt;
        }
    
        organization
          "Broadband Forum <https://www.broadband-forum.org>
         Common YANG Work Area";
    
        contact
          "Comments or questions about this Broadband Forum YANG module
         should be directed to <mailto:help@broadband-forum.org>.
    
         Editor:      Ken Kerpez, ASSIA, Inc.
    
         Editor:      Joey Boyd, Adtran
    
         PS Leader:   Joey Boyd, Adtran
    
         WA Director: Sven Ooghe, Nokia
    
         WA Director: Joey Boyd, Adtran";
    
        description
          "This submodule contains a collection of YANG definitions for
         managing the Physical Medium Dependent (PMD) control object.
    
         Copyright (c) 2016-2022 Broadband Forum
    
         Redistribution and use in source and binary forms, with or
         without modification, are permitted provided that the following
         conditions are met:
    
         1. Redistributions of source code must retain the above copyright
            notice, this list of conditions and the following disclaimer.
    
         2. Redistributions in binary form must reproduce the above
            copyright notice, this list of conditions and the following
            disclaimer in the documentation and/or other materials
            provided with the distribution.
    
         3. Neither the name of the copyright holder nor the names of its
            contributors may be used to endorse or promote products
            derived from this software without specific prior written
            permission.
    
         THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
         CONTRIBUTORS \"AS IS\" AND ANY EXPRESS OR IMPLIED WARRANTIES,
         INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
         MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
         DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
         CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
         SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
         NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
         LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
         CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
         STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
         ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
         ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
    
         The above license is used as a license under copyright only.
         Please reference the Forum IPR Policy for patent licensing terms
         <https://www.broadband-forum.org/ipr-policy>.
    
         Any moral rights which are necessary to exercise under the above
         license grant are also deemed granted under this license.
    
         This version of this YANG module is part of TR-355a4; see
         the TR itself for full legal notices.";
    
        revision "2022-05-23" {
          description
            "Amendment 4.
           * Approval Date:    2022-05-23
           * Publication Date: 2022-05-23.";
          reference
            "TR-355a4: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-4.pdf>";
    
        }
    
        revision "2020-10-13" {
          description
            "Amendment 3.
           * Approval Date:    2020-10-13
           * Publication Date: 2020-10-13.";
          reference
            "TR-355a3: YANG Modules for FTTdp Management
            	    <https://www.broadband-forum.org/download/
            		   TR-355_Amendment-3.pdf>";
    
        }
    
        revision "2019-06-11" {
          description
            "Amendment 2.
           * Approval Date:    2019-06-11
           * Publication Date: 2019-06-11.";
          reference
            "TR-355a2: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Amendment-2.pdf>";
    
        }
    
        revision "2018-10-01" {
          description
            "Amendment 1.
           * Approval Date:    2018-10-01
           * Publication Date: 2018-10-01.";
          reference
            "TR-355a1: YANG Modules for FTTdp Management
            	  <https://www.broadband-forum.org/technical/download/
            		 TR-355_Amendment-1.pdf>";
    
        }
    
        revision "2016-07-18" {
          description
            "Initial revision.
           * Approval Date:    see revision date above.
           * Publication Date: 2016-08-05.";
          reference
            "TR-355: YANG Modules for FTTdp Management
            	<https://www.broadband-forum.org/technical/download/
            		 TR-355.pdf>";
    
        }
    
    
        typedef pmd-function {
          type enumeration {
            enum "uer-measurement" {
              value 1;
              description
                "Triggers the Central Office (CO) Single Ended Line Test
               Physical Medium Dependent (SELT-PMD) to start an
               Uncalibrated Echo Response (UER) measurement.";
              reference
                "ITU-T G.996.2 clause A.2.3.1 (SELT-UME-C)";
    
            }
            enum "qln-measurement" {
              value 2;
              description
                "Triggers the Central Office (CO) Single Ended Line Test
               Physical Medium Dependent (SELT-PMD) to start a Quiet Line
               Noise (QLN) measurement.";
              reference
                "ITU-T G.996.2 clause A.2.3.3 (SELT-QME-C)";
    
            }
          }
          description
            "The Central Office (CO) Single Ended Line Test Physical Medium
           Dependent (SELT-PMD) function.";
        }
    
        grouping selt-pmd-control {
          description
            "Defines the parameters contained in the PMD control object.";
          leaf uer-measurement-enable-c {
            type boolean;
            default "false";
            status deprecated;
            description
              "If true, triggers the Central Office (CO) Single Ended Line
             Test Physical Medium Dependent (SELT-PMD) to start an
             Uncalibrated Echo Response (UER) measurement.
    
             A configuration change back to 'false' is required before
             initiating another update.";
            reference
              "ITU-T G.996.2 clause A.2.3.1 (SELT-UME-C)";
    
          }
    
          leaf qln-measurement-enable-c {
            type boolean;
            default "false";
            status deprecated;
            description
              "If true, triggers the Central Office (CO) Single Ended Line
             Test Physical Medium Dependent (SELT-PMD) to start a Quiet
             Line Noise (QLN) measurement.
    
             A configuration change back to 'false' is required before
             initiating another update.";
            reference
              "ITU-T G.996.2 clause A.2.3.3 (SELT-QME-C)";
    
          }
        }  // grouping selt-pmd-control
    
        grouping pmd-control {
          description
            "Physical Medium Dependent (PMD) control configuration.";
          leaf pmd-control {
            type enumeration {
              enum "disable" {
                value 0;
                description
                  "The Central Office (CO) Single Ended Line Test Physical
                 Medium Dependent (SELT-PMD) is not configured for a
                 measurement.";
              }
              enum "enable" {
                value 1;
                description
                  "The Central Office (CO) Single Ended Line Test Physical
                 Medium Dependent (SELT-PMD) is configured for a
                 measurement.";
              }
            }
            default "disable";
            description
              "The Central Office (CO) Single Ended Line Test Physical
             Medium Dependent (SELT-PMD) is by default 'disable'. When
             'disable', the line is in normal operation (e.g., in the L0
             state if the line is configured with AdminStatus=up). When
             'enable', the Access Node (AN)/Distribution Point Unit (DPU)
             Maintenance Entity (ME) shall force the line to the L3
             state.";
          }
    
          action request-pmd-function-c {
            description
              "A measurement is by default not triggered. A measurement is
             triggered when the action is sent with the appropriate
             function specified. One or more measurements may be triggered
             while the Central Office (CO) Single Ended Line Test Physical
             Medium Dependent (SELT-PMD) is configured 'enable', possibly
             with different CO SELT-PMD configuration parameters. If the
             triggered measurement cannot be executed, then the
             Access Node (AN)/Distribution Point Unit (DPU) Maintenance
             Entity (ME) rejects this action and the CO SELT-PMD status
             remains 'inactive'.";
            input {
              leaf pmd-function {
                type union {
                  type enumeration {
                    enum "abort" {
                      value 0;
                      description
                        "Triggers the Central Office (CO) Single Ended Line
                       Test Physical Medium Dependent (SELT-PMD) to abort
                       any currently ongoing measurement.";
                    }
                  }
                  type pmd-function;
                }
                description
                  "The action being requested.";
              }
            }
          }  // rpc request-pmd-function-c
        }  // grouping pmd-control
      }  // submodule bbf-selt-pmd-control-body
    